Attivo maturo
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, On-delay setting range 10-180s, connection by spring terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).
Country of Origin
FR
Part Number
LADT43
Tariff Code
8536509065
UNSPSC
39121529
Metodi di pagamento:
Migliore offerta da:
DEFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 21-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Environment

Ambient Air Temperature For Operation
-40-70 °C
Ip Degree Of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature For Storage
-60-80 °C
Environmental Characteristic
normal environment
Protective Treatment
TH IEC 60068
Operating Altitude
9842.52 ft (3000 m)

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110702
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions

Complementary

Non-Overlap Time
1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
Permissible Short-Time Rating
100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms
Minimum Switching Current
5 mA
Height
48 mm
Protection Type
gG fuse 10 A
Insulation Resistance
> 10 MOhm
Irms Rated Making Capacity
140 A AC || 250 A DC
Connections - Terminals
spring terminals 2 2.5-2.5 mm²flexible without cable end || spring terminals 2 2.5-2.5 mm²rigid
Minimum Switching Voltage
17 V
Mechanical Durability
5 Mcycles
Width
44 mm
Depth
61 mm

Specifications

Product Certifications
IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
Standards
EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5
Timer Type
on delay
[Ue] Rated Operational Voltage
690 V AC 25...400 Hz
Range Compatibility
TeSys D CAD || TeSys D LC1D || TeSys Deca CAD || TeSys Deca LC1D
Product Or Component Type
time delay auxiliary contact block
Product Name
TeSys Deca
Range
TeSys || TeSys Deca
Mounting Location
front
Pole Contact Composition
1 NO + 1 NC
[Ui] Rated Insulation Voltage
690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1
[Ie] Rated Operational Current
6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
Time Delay Range
10...180 s
Auxiliary Contacts Operation
time delay