Schneider Electric LC1D186P7

IEC Contact, TeSys Deca, 18A, 3-phase, 3 pole, 10HP at 480VAC

1 / 1
Schneider Electric LC1D186P7 IEC Contact, TeSys Deca, 18A, 3-phase, 3 pole, 10HP at 480VAC — Elettronica e PCB
Immagine di catalogo del produttore

Descrizione del prodotto

Ciclo di vita:

TeSys D contactors are designed for seamless integration into control systems, offering a wide range of applications. These contactors are available in multiple ratings, accommodating inductive motor loads up to 150 amps and resistive loads up to 200 amps. This specific model is an IEC contactor with a rating of 18A for inductive loads and can be mounted on DIN rail or directly on a panel.

The contactor boasts both horsepower and kilowatt motor ratings for international acceptance, supporting various voltage levels. It is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC, and 15HP at 600VAC in three-phase applications, as well as 1HP at 115VAC and 3HP at 240VAC in single-phase applications. The contactor comes with a 230VAC 50/60Hz coil.

This contactor features one normally open and one normally closed auxiliary contact as standard, with the NC contact being mirror certified. It uses ring-lug screw terminals for load and auxiliary connections. A comprehensive line of accessories ensures compatibility with diverse applications.

The contactor measures 3.03 inches in height, 1.77 inches in width, and 3.39 inches in depth, weighing approximately 0.73 lbs. It is certified to UL, CSA, IEC, CCC, EAC, and Marine standards, as well as RoHS/REACh, making it a green premium product.

Invia la richiesta
Metodi di pagamento:

Dettagli dell'offerta

Migliore offerta da:
Fornitore di fiducia — Romania, membro dal 2023, 1–4 dipendenti
Disponibilità:
1 pz.
Su richiesta
Aggiornato il: 22-08-2026
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Il venditore è responsabile della spedizione del prodotto e della fatturazione

Specifiche tecniche

Product Certifications
CCC || LROS (Lloyds register of shipping) || GL || RINA || UL || CSA || DNV || GOST || BV || UKCA
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Offerte Disponibili

(2)
LC1D186P7 Schneider Electric, Elettronica e PCB

Schneider Electric

Disponibile:
0 pz.
Su richiesta
Aggiornato il: 04-09-2026
Offerta da:
Fornitore di fiducia — Germania, membro dal 2024

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni
Offerta con tempi di consegna del produttore
Direttamente dal produttore, con tempi di consegna confermati, prevedibili e completamente trasparenti.
Preventivo

Documenti

Scheda tecnica

Scheda tecnica per Schneider Electric LC1D186P7, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti compatibili

GV2G245 Schneider Electric
GV2G245
Schneider Electric
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers
GV2G445 Schneider Electric
GV2G445
Schneider Electric
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers
LA4DFB Schneider Electric
LA4DFB
Schneider Electric
TeSys Deca low signal interface module, for control of contactors LC
LA4DT0U Schneider Electric
LA4DT0U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DT2U Schneider Electric
LA4DT2U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DT4U Schneider Electric
LA4DT4U
Schneider Electric
TeSys Deca electronic timer module for LC1D09-D38, LC1D40A-D80A, LC1D80-D150 (3P) contactors
LA4DWB Schneider Electric
LA4DWB
Schneider Electric
TeSys Deca low signal interface module, for control of contactors LC
LAD4RCU Schneider Electric
LAD4RCU
Schneider Electric
TeSys D suppressor module, for LC1D09-D38, LC1DT20-DT40 contactors and CAD control relays
LAD4VU Schneider Electric
LAD4VU
Schneider Electric
A TeSys D suppressor module designed for LC1D09-D38 and LC1DT20-DT40 contactors and CAD control relays. It provides varistor protection limiting transient voltage to 2 Uc max.
LAD6K10M Schneider Electric
LAD6K10M
Schneider Electric
TeSys Deca mechanical latch block, for LC1D09-D80A, LC1DT20-DT80A contactors and CAD control relays (except devices with low consumption coils)
LAD8N116 Schneider Electric
LAD8N116
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD9ET1S Schneider Electric
LAD9ET1S
Schneider Electric
TeSys D safety protective cover, for preventing access to the moving contact carrier
LAD9R1 Schneider Electric
LAD9R1
Schneider Electric
TeSys D kit for reversing contactors assembly, for 3-pole contactors LC1D09-D38
LAD9R1V Schneider Electric
LAD9R1V
Schneider Electric
TeSys D kit for reversing contactors assembly, for 3-pole contactors LC1D09-D38
LAD9V2 Schneider Electric
LAD9V2
Schneider Electric
TeSys D mechanical interlock, for contactors LC1D09-D38 and LC1DT20-DT40
LADN026 Schneider Electric
LADN026
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F
LADN116 Schneider Electric
LADN116
Schneider Electric
Auxiliary contact block providing 1NO + 1NC contacts rated up to 10A at 690V AC, compatible with TeSys D and TeSys F contactors.
LADN206 Schneider Electric
LADN206
Schneider Electric
A high-reliability auxiliary contact block for TeSys D and F contactors, featuring 10A 690V AC rating and ring-lug screw terminals.
LADN226 Schneider Electric
LADN226
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F
LADN316 Schneider Electric
LADN316
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F
LADN406 Schneider Electric
LADN406
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F
LADR06 Schneider Electric
LADR06
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D and control relays CAD
LADR26 Schneider Electric
LADR26
Schneider Electric
The TeSys Deca Time Delay Auxiliary Contact Block is a reliable solution for controlling contactors and relays. It offers 1NO+1NC contacts rated up to 10A 690V AC, with an off-delay setting range of 1-30 seconds.
LADR46 Schneider Electric
LADR46
Schneider Electric
Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10-180s, front, lugs-ring terminals
LADT26 Schneider Electric
LADT26
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D and control relays CAD
LADT46 Schneider Electric
LADT46
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD

Ricambi

LXD1P7 Schneider Electric
LXD1P7
Schneider Electric
TeSys D replacement coil 230V AC 50/60Hz, for TeSys D contactors

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia