Schneider Electric

LC1D326BLS207

1 / 1
thumbnail

Descrizione

Attivo maturo
This TeSys D contactor has been designed for motor control in railway applications. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.18 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
Country of Origin
FR
Part Number
LC1D326BLS207
Tariff Code
85364900
EAN
3389118234604
UNSPSC
39121529
€219.00
net
1
Metodi di pagamento:
Migliore offerta da:
DEFornitore Automa.Net di fiducia
Disponibilità:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 25 Parts In-Stock da 11 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (10)

LC1D326BLS207 product image
Schneider Electric

LC1D326BLS207

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
£273.49
net
LC1D326BLS207 product image
Schneider Electric

LC1D326BLS207

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
ESFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€314.50
net
LC1D326BLS207 product image
Schneider Electric

LC1D326BLS207

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
ITFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€314.50
net
LC1D326BLS207 product image
Schneider Electric

LC1D326BLS207

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
NLFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€314.50
net
LC1D326BLS207 product image
Schneider Electric

LC1D326BLS207

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
FRFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€320.79
net
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€57.03

Environment

Height
85 mm
Climatic Withstand
IACS E10 || IEC 60947-1 Annex Q category D
Net Weight
0.375 kg
Ambient Air Temperature For Storage
-60-80 °C
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Fire Resistance
850 °C IEC 60695-2-1
Width
45 mm
Depth
101 mm

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2205004
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
IEC || CCC || EAC || UA || TR || UKCA
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
Power Dissipation Per Pole
2 W AC-3 || 5 W AC-1 || 2 W AC-3e
Average Impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit || 50 A (at 60 °C) for power circuit
Control Circuit Voltage Limits
0.1...0.25 Uc -40-70 °C drop-out DC || 0.7...1.25 Uc -40-70 °C operational DC
Mounting Support
rail || plate
Contact Compatibility
M5
Control Circuit Type
DC low consumption
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || EN 45545: R22 HL3 || EN 45545: R26 HL3 || DIN 5510-2
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W
4-4 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
550 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Pole Contact Composition
3 NO
Connections - Terminals
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 12 mm
Coil Technology
with integral suppression device
Time Constant
37 ms
Operating Time
55...75 ms closing || 16...32 ms opening
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h 60 °C
Tightening Torque
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4 || power circuit 2.5 N.m lugs-ring terminals flat Ø 6 mm M4
Electrical Durability
1.65 Mcycles 32 A AC-3 <= 440 V || 1.4 Mcycles 50 A AC-1 <= 440 V || 1.65 Mcycles 32 A AC-3e <= 440 V
Mechanical Durability
30 Mcycles
Inrush Power In W
4-4 W 20 °C)
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Compatibility Code
LC1D
Operating Altitude
0...9842.52 ft (0...3000 m)
Overvoltage Category
III
Motor Power Kw
7.5 kW at 220/230 V AC 50 Hz (AC-3) || 15 kW at 380/400 V AC 50 Hz (AC-3) || 15 kW at 415 V AC 50 Hz (AC-3) || 15 kW at 440 V AC 50 Hz (AC-3) || 18.5 kW at 500 V AC 50 Hz (AC-3) || 18.5 kW at 660/690 V AC 50 Hz (AC-3) || 7.5 kW at 220/230 V AC 50 Hz (AC-3e) || 15 kW at 380/400 V AC 50 Hz (AC-3e) || 15 kW at 415 V AC 50 Hz (AC-3e) || 15 kW at 440 V AC 50 Hz (AC-3e) || 18.5 kW at 500 V AC 50 Hz (AC-3e) || 18.5 kW at 660/690 V AC 50 Hz (AC-3e)
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
Protective Cover
with

Specifications

[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz
Range Of Product
TeSys Deca
Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Range
TeSys || TeSys Deca
Utilisation Category
AC-3 || AC-1 || AC-3e
[Ie] Rated Operational Current
32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Poles Description
3P
Device Short Name
LC1D

Modelli CAD

traceparts
traceparts
Scaricare