Contactor body,TeSys F,3P(3NO), AC-3, <=440V 115A, without coil
LC1F115
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
$701.39
1
Metodi di pagamento:
Un totale di 82 Parts In-Stock da 27 Distributors

Additional Information

Part Number
LC1F115
UNSPSC
39121529
Tariff Code
8536490065
Country of Origin
CZ

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed6 Gn, 5...300 Hz || shocks contactor open9 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Ambient Air Temperature For Operation
-40-60 °C
Height
162 mm
Net Weight
3.83 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Width
163.5 mm
Depth
171 mm
Permissible Ambient Air Temperature Around The Device
60-70 °C at Uc

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP060301EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100405
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
RINA || ABS || CSA || DNV || RMRoS || BV || LROS (Lloyds register of shipping) || UL || CB || UKCA
Power Dissipation Per Pole
15 W AC-1 || 5 W AC-3
Average Impedance
0.37 mOhm - Ith 200 A 50 Hz
Control Circuit Voltage Limits
operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil || drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil
[Ith] Conventional Free Air Thermal Current
200 A (at 40 °C)
Standards
EN 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-4-1 || IEC 60947-1
[Uc] Control Circuit Voltage
24...575 V AC 40...400 Hz with LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V DC with LXE coil
Mounting Support
plate
Rated Breaking Capacity
920 A conforming to IEC 60947-4-1
Irms Rated Making Capacity
1150 A conforming to IEC 60947-4-1
Associated Fuse Rating
125 A aM at <= 440 V || 200 A gG at <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
power circuit lugs-ring terminals 1 95-95 mm² || power circuit connector 1 95-95 mm² || power circuit bar 2 20 x 3 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end
Inrush Power In Va
590-855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 543-665 VA (at 20 °C)with LX4 coil || 280-310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 270-320 VA (at 20 °C)with LXE coil
Maximum Operating Rate
2400 cyc/h 55 °C
Operating Time
35 ms closing with LX9 coil || 130 ms opening with LX9 coil || 30...40 ms closing with LX4 coil || 30...50 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil
Tightening Torque
power circuit 10 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m
Mechanical Durability
10 Mcycles
Compatibility Code
LC1F
Hold-In Power Consumption In Va
6.6-8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 3.94-4.83 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil
Overvoltage Category
III
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
1100 A 40 °C - 10 s || 640 A 40 °C - 30 s || 520 A 40 °C - 1 min || 400 A 40 °C - 3 min || 320 A 40 °C - 10 min
Heat Dissipation
5.9-7.2 W || 2.2-5.5 W

Specifications

[Ue] Rated Operational Voltage
<= 690 V AC 50/60 Hz || <= 460 V DC
Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Product Name
TeSys F
Range
TeSys
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
200 A 40 °C) <= 440 V AC-1 || 115 A 55 °C) <= 440 V AC-3
Utilisation Category
AC-1 || AC-4 || AC-3
Poles Description
3P
Motor Power Kw
55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415 V AC 50/60 Hz (AC-3) || 59 kW at 440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 220...240 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 18.5 kW at 400 V AC 50/60 Hz (AC-4)
Device Short Name
LC1F

Documenti

Data Sheet

Scaricare

Modelli CAD

Parti in traccia
Parti in traccia
Scaricare