1 / 1
thumbnail

Descrizione

Attivo maturo
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Country of Origin
CN
Part Number
LC1G265BEEA
Tariff Code
85364190
EAN
3606481922267
UNSPSC
39121529
£1,831.67
net
1
Metodi di pagamento:
Migliore offerta da:
GBFornitore Automa.Net di fiducia
Disponibilità:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 22 Parts In-Stock da 11 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (10)

LC1G265BEEA product image
Schneider Electric

LC1G265BEEA

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Offerta da:
FRFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€2,142.30
net
LC1G265BEEA product image
Schneider Electric

LC1G265BEEA

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Offerta da:
ESFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€2,142.30
net
LC1G265BEEA product image
Schneider Electric

LC1G265BEEA

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€2,142.30
net
LC1G265BEEA product image
Schneider Electric

LC1G265BEEA

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Offerta da:
ITFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€2,142.30
net
LC1G265BEEA product image
Schneider Electric

LC1G265BEEA

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 07-11-2024
Offerta da:
NLFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€2,142.30
net
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€456.86

Complementary

Product Certifications
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Height
290 mm
Power Dissipation Per Pole
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Average Impedance
0.000144 Ohm
Auxiliary Contact Composition
1 NO + 1 NC
Connection Pitch
45 mm
[Ith] Conventional Free Air Thermal Current
385 A (at 40 °C)
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1
Mounting Support
plate
Hold-In Power Consumption In W
6.4-6.4 W
Rated Breaking Capacity
2380 A at 440 V
Irms Rated Making Capacity
3320 A at 440 V
Associated Fuse Rating
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Net Weight
8.2 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
540-540 VA
Pole Contact Composition
3 NO
Connections - Terminals
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end || control circuit: push-in 2 0.5-1.0 mm² with cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology
built-in bidirectional peak limiting
Operating Time
40...70 ms closing || 15...50 ms opening
Maximum Operating Rate
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Mechanical Durability
8 Mcycles
Tightening Torque
35 N.m
Compatibility Code
LC1G
Hold-In Power Consumption In Va
17.9-17.9 VA
Width
140 mm
Overvoltage Category
III
Depth
226 mm
Maximum Horse Power Rating
75 hp at 200/208 V 60 Hz || 100 hp at 230/240 V 60 Hz || 200 hp at 460/480 V 60 Hz || 200 hp at 575/600 V 60 Hz
Motor Power Kw
75 kW at 230 V AC 50/60 Hz (AC-3e) || 132 kW at 400 V AC 50/60 Hz (AC-3e) || 132 kW at 415 V AC 50/60 Hz (AC-3e) || 160 kW at 440 V AC 50/60 Hz (AC-3e) || 160 kW at 500 V AC 50/60 Hz (AC-3e) || 200 kW at 690 V AC 50/60 Hz (AC-3e) || 160 kW at 1000 V AC 50/60 Hz (AC-3e) || 75 kW at 230 V AC 50/60 Hz (AC-3) || 132 kW at 400 V AC 50/60 Hz (AC-3) || 132 kW at 415 V AC 50/60 Hz (AC-3) || 160 kW at 440 V AC 50/60 Hz (AC-3) || 160 kW at 500 V AC 50/60 Hz (AC-3) || 200 kW at 690 V AC 50/60 Hz (AC-3) || 160 kW at 1000 V AC 50/60 Hz (AC-3) || 75 kW at 230 V AC 50/60 Hz (AC-4) || 132 kW at 400 V AC 50/60 Hz (AC-4) || 132 kW at 415 V AC 50/60 Hz (AC-4) || 150 kW at 440 V AC 50/60 Hz (AC-4) || 160 kW at 500 V AC 50/60 Hz (AC-4) || 160 kW at 690 V AC 50/60 Hz (AC-4) || 160 kW at 1000 V AC 50/60 Hz (AC-4)
[Ui] Rated Insulation Voltage
1000 V
Inrush Power In W
380 W
[Icw] Rated Short-Time Withstand Current
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2105013
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI2105013
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Specifications

[Uc] Control Circuit Voltage
24...48 V AC 50/60 Hz || 24...48 V DC
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz || <= 460 V DC
Range Of Product
TeSys Giga
Control Circuit Voltage Limits
operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Contactor Application
power switching || motor control
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
[Ie] Rated Operational Current
385 A (at <40 °C) at <= 1000 V AC-1 || 265 A (at <60 °C) at <= 440 V AC-3
Poles Description
3P
Device Short Name
LC1G

Environment

Ambient Air Temperature For Operation
-25-60 °C
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Mechanical Robustness
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Color
dark grey
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Modelli CAD

traceparts
traceparts
Scaricare