Schneider Electric
LV430673
1 / 1
Descrizione
This Compact NSX160H is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 80A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX160H is part of Schneider Electric EcoStruxure Power architecture.- Country of Origin
- PL
- Part Number
- LV430673
- Tariff Code
- 85362090
- EAN
- 3606480011580
- UNSPSC
- 39121633
Metodi di pagamento:
- Migliore offerta da:
- Fornitore Automa.Net di fiducia
- Disponibilità:
- 1 pz.DisponibileAggiornato il: 08-11-2024
- Garanzia:
- 12 mesi
- Consegna stimata:
- Su richiesta
- Condizione:
- Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia
Specifications
- Network Frequency
- 50/60 Hz
- Line Rated Current
- 80 A 40 °C
- Trip Unit Name
- TM-D
- Range Of Product
- ComPact NSX100...250
- [Ue] Rated Operational Voltage
- 690 V AC 50/60 Hz
- Trip Unit Protection Functions
- LI
- Network Type
- AC
- Protected Poles Description
- 3t
- Product Or Component Type
- circuit breaker
- Product Name
- ComPact NSX
- Range
- ComPact
- Control Type
- toggle
- Utilisation Category
- category A
- Mounting Mode
- fixed
- Breaking Capacity
- 10 kA 600 V AC 50/60 Hz UL 508 || 85 kA 240 V AC 50/60 Hz UL 508 || 65 kA 480 V AC 50/60 Hz UL 508 || 10 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2
- Suitability For Isolation
- yes EN/IEC 60947-2
- Poles Description
- 3P
- Breaking Capacity Code
- H 70 kA 415 V AC
- Device Application
- distribution
- Device Short Name
- NSXm 160H
- Trip Unit Technology
- thermal-magnetic
Contractual warranty
- Warranty
- 18 months
Complementary
- [Ics] Rated Service Breaking Capacity
- 10 kA 660/690 V AC 50/60 Hz IEC 60947-2 || 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 525 V AC 50/60 Hz IEC 60947-2 || 50 kA 500 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2 || 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Height
- 161 mm
- Earth-Leakage Protection
- without
- Mounting Support
- backplate
- Downside Connection
- front
- Number Of Slots
- 5
- Protection Type
- L : for overload protection (thermal) || I : for short-circuit protection (magnetic)
- Long Time Delay Adjustment Type
- fixed
- Net Weight
- 2.2 kg
- [Tr] Long-Time Delay Adjustment Range
- 120-400 s 1.5 x In || 15-15 s 6 x Ir
- Electrical Durability
- 7500 cycles 690 V In || 15000 cycles 690 V In/2 || 20000 cycles 440 V In || 40000 cycles 440 V In/2
- Short-Time Delay Adjustment Type
- fixed
- Long Time Pick-Up Adjustment Type Ir
- adjustable
- Long Time Pick-Up Adjustment Range
- 0.7...1 x In
- Upside Connection
- front
- [Ui] Rated Insulation Voltage
- 800 V AC 50/60 Hz
- Trip Unit Rating
- 80-80 A 40 °C
- Mechanical Durability
- 40000 cycles
- [Isd] Short-Time Pick-Up Adjustment Range
- 640 A
- Connection Pitch
- 35 mm
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Width
- 105 mm
- Depth
- 86 mm
- Short-Time Pick-Up Adjustment Type Isd
- fixed
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP120606EN
- Sustainable Offer Status
- Green Premium product
- California Proposition 65
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI120604EN
- Eu Rohs Directive
- Compliant
Environment
- Product Certifications
- CCC || EAC || Marine
- Ik Degree Of Protection
- IK07 IEC 62262
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/IEC 60947
- Ip Degree Of Protection
- IP40 conforming to IEC 60529
- Electrical Shock Protection Class
- class II
- Pollution Degree
- 3 IEC 60664-1
- Ambient Air Temperature For Storage
- -50-85 °C
- Relative Humidity
- 0-95 %
- Operating Altitude
- 0...6561.68 ft (0...2000 m) without derating || 2000 m...5000 m with derating
- Overvoltage Category
- class II
Modelli CAD
traceparts
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro