1 / 1
thumbnail

Descrizione

Attivo maturo
TeSys F AC coil 460/480/500V 40-400Hz (voltage code T7/S7), low sealed consumption, high tolerance to voltage drops, for TeSys F 3-pole and 4-pole contactors LC1 F115, F150, FG150. It operates in voltage limits 0.85-1.1 Uc and environments until 55°C. It provides high operating rates to the contactor, until 2400 cycles/hour. Green Premium compliant (RoHS/REACh).
Country of Origin
CZ
Part Number
LX9FF500
Tariff Code
85059029
EAN
3389110083972
UNSPSC
39121529
Metodi di pagamento:
Migliore offerta da:
DEAutoma.Net Fornitore
Disponibilità:
6 pz.
Disponibile
Aggiornato il: 14-06-2023
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 7 Parts In-Stock da 2 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (1)

LX9FF500 product image
Schneider Electric

LX9FF500

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€55.93

Environment

Ambient Air Temperature For Operation
-5-55 °C
Net Weight
0.43 kg

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111201EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
China Rohs Regulation
X
Circularity Profile
ENVEOLI111214EN_V1
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Control Circuit Voltage Limits
operational 0.85...1.1 Uc 55 °C) || drop-out 0.2...0.55 Uc 55 °C)
Inrush Power In Va
690-855 VA 40...400 Hz (at 20 °C)
Coil Technology
without built-in suppressor module
Hold-In Power Consumption In Va
6.6-8.1 VA 40...400 Hz (at 20 °C)
Heat Dissipation
5.9-7.2 W

Specifications

Average Resistance
262 Ohm inrush 20 °C || 10300 Ohm holding 20 °C
[Uc] Control Circuit Voltage
500 V AC 40...400 Hz
Control Circuit Type
AC 40...400 Hz low consumption
Range Compatibility
TeSys TeSys F LC1F contactor
Product Or Component Type
specific contactor coil
Range
TeSys
Inductance Of Closed Circuit
36 H
Maximum Operating Rate
2400 cyc/h 55 °C
Operating Time
130 ms opening || 35 ms closing
Product Compatibility
LC1F150 || LC1F115
Device Short Name
LX9FF
Mechanical Durability
10 Mcycles