Schneider Electric
METSEEM3561A
1 / 1
Descrizione
Attivo maturo
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xxA models are designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter. Not recommanded for high harmonic application. Current input from 20A to 5000A with the Rogowski coil, ANSI C12.20 0.5% accuracy, IEC 62053-22 class 0.5S. Native BACnet is provided to suit a wide variety of applications. Additional 2 pulse inputs provide an easy way to incorporate simple WAGES sensors using a BACnet system. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm and product weight 280 g.- Country of Origin
- US
- Part Number
- METSEEM3561A
- EAN
- 39121032
- UNSPSC
- 39121032
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Network Frequency
- 60 Hz || 50 Hz
- Communication Port Support
- screw terminal block RS485
- [Ue] Rated Operational Voltage
- 90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
- Standards
- CSA C22.2 No 14-05 || IEC 61010-1 || UL 508
- Mounting Support
- DIN rail
- Power Consumption In Va
- 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
- Product Certifications
- CE IEC 61010 || cULus UL 508
- Type Of Measurement
- active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
- Communication Port Protocol
- BACnet MS/TP 9600 bauds...115200 bauds (automatic detection) - 2-wire
- Communication Service
- total cumulated energy || total cumulated active energy
- Ride-Through Time
- 100 ms 120 V AC
- Display Digits
- 5
- Number Of Inputs
- 2 pulse
- Tamperproof Of Settings
- protected by access code
- Measurement Current
- 20-5000 A
- Information Displayed
- status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
- Function Available
- fixed or rolling block || external synchronisation to communication
- Mounting Mode
- by screws || clip-on
- Local Signalling
- Red LED threshold reached || Green flashing LED output signal
- Power Consumption In W
- 3 W 300-300 V
- Measurement Accuracy
- power +/- 0.5 % || energy +/- 0.5 %
- Technology Type
- electronic
- Poles Description
- 3P + N
- Data Recording
- energy consumption logs
- Analogue Input Type
- Rogowski coil 50...5000 A
- Display Type
- Backlit LCD
- Device Application
- sub billing || partial meter
- Accuracy Class
- class 0.5S power IEC 62053-22 || class 0.5S energy IEC 62053-22 || class 0.5S power ANSI C12.20 || class 0.5S energy ANSI C12.20
- Rated Voltage
- 90-347 V
Environment
- Ambient Air Temperature For Operation
- -30-70 °C
- Height
- 91 mm
- 9 Mm Pitches
- 12
- Color
- dark grey
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 0-95 %
- Width
- 107 mm
- Depth
- 59 mm
Specifications
- Product Or Component Type
- energy meter
- Product Name
- PowerLogic EM3500
- Range
- PowerLogic
- Device Short Name
- EM3561A
- Metering Type
- current I1, I2, I3, Iavg || peak demand power PM, QM, SM || demand power P, Q, S || voltage U21, U32, U13, V1, V2, V3
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro