Schneider Electric
METSEION7410A
Power quality meter, PowerLogic ION7400, Advanced, integrated display, 512 MB, 5...
- Part Number
- METSEION7410A
- Tariff Code
- 9028300000
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Additional Information
- Part Number
- METSEION7410A
- Tariff Code
- 9028300000
Complementary
- Communication Network Type
- IPv6 (internet protocol)
- Network Frequency
- 50 Hz || 60 Hz
- Communication Port Support
- ETHERNET || screw terminal block RS485 || optical probe fiber optic || mini B USB USB
- Power Quality Analysis
- EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class A power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || IEC 62586 programmablity (logic and math functions) || IEC 62586 power quality monitoring || IEC 61000-4-15 2014 flicker || disturbance direction detection || rapid voltage change
- Height
- 112 mm
- Measurement Voltage
- 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
- Sampling Rate
- 512 samples/cycle
- Standards
- IEC 61557-12 || IEC 61326-1 || IEC 62052-11 || IEC 62053-24 || IEC 62053-22 || IEEE 1588 || IEC 62586
- Memory Capacity
- 512 MB
- Number Of Outputs
- 1 pulse
- Product Certifications
- CE || cULus || N998
- Type Of Measurement
- current || voltage || frequency total || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms || active and reactive energy total || apparent energy per phase, rms
- Communication Port Protocol
- Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 115 kbauds - 2-wire || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004 || Ansi C12.19 10/100 Mbit/s || DLMS
- Power Consumption In W
- 17 W
- Frequency Measurement Range
- 42-69 Hz
- Communication Service
- SNMP || SMTP e-mail notification || RSTP support || DHCP || NTP time synchronization || PTP time synchronization
- Display Resolution
- 320 x 240 pixels QVGA
- Number Of Inputs
- 3 digital 30 V AC || 3 digital 60 V DC
- Net Weight
- 706 g
- Type Of Installation
- indoor installation
- Depth
- 78.5 mm
- Measurement Current
- 50-10000 mA
- Information Displayed
- voltage || current || frequency || power || energy consumption || harmonic distortion
- [Us] Rated Supply Voltage
- 20...60 V DC +/- 10 %
- Mounting Mode
- flush-mounted
- Measurement Accuracy
- current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
- Mounting Support
- framework
- Poles Description
- 1P + N || 3P + N || 3P
- Data Recording
- data logs || sag and swell logs || waveform logs || trending/forecasting || sequence of event recording || GPS synchronisation || harmonics logs || time stamping || alarm logs || event logs || min/max of instantaneous values || 64 data recorders
- Line Rated Current
- 10 A || 1 A || 5 A
- Cybersecurity
- enable/disable communication ports || port hardening || Syslog protocol support || password protection || robust security logs
- Isolation Voltage
- III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
- Analogue Input Type
- voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
- Web Services
- customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
- Width
- 98 mm
- Display Type
- colour TFT LCD
- Device Application
- revenue billing || WAGES metering || data aggregation || power monitoring
- Accuracy Class
- class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12 || class 0.2 frequency IEC 61557-12 || class 0.2 active energy IEC 61557-12
- Installation Category
- III
Specifications
- Product Or Component Type
- power meter
- Product Name
- PowerLogic ION7400
- Range
- PowerLogic
- Device Short Name
- ION7410
Offer Sustainability
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP1512006EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1512006EN
- Eu Rohs Directive
- Compliant with Exemptions
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Electromagnetic Compatibility
- electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55022 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions conforming to FCC part 15 || conducted and radiated emissions conforming to ICES-003 || conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 || surge withstand (2...150 Hz) conforming to IEEE C37.90.1
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 5-95 %
- Ip Degree Of Protection
- front IP54 IEC 60529 || body IP30 IEC 60529
- Operating Altitude
- 9842.52 ft (3000 m)
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro