Schneider Electric

METSEION92040

1 / 1
thumbnail

Descrizione

Attivo maturo
The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Wide control power range of 90 to 480 VAC or 110 to 480 VDC. DIN rail mounting with remote display and panel mounting (with back to back adapter), plus 2 display options, further enhance the flexibility and adaptability of the ION9000.
Country of Origin
MX
Part Number
METSEION92040
Tariff Code
90283090
EAN
3606481352316
UNSPSC
83101808
Metodi di pagamento:
Migliore offerta da:
GBFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 21-10-2024
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Complementary

Network Frequency
50 Hz || 60 Hz
[Us] Rated Supply Voltage
90...480 V AC 45...66 Hz +/- 10 % || 90...120 V AC 400 Hz +/- 10 % || 110...480 V DC +/- 15 %
Communication Port Support
2 RS485 removable screw terminal block
Power Quality Analysis
EN 50160 compliance checking || IEEE 519 harmonic limit || IEC 61000-4-30 class A compliance reporting || IEEE 519 compliance reporting || waveform capture || total demand distortion || total harmonic distortion || up to the 63rd harmonic || up to the 127th harmonic with software || disturbance direction detection || dip, swell and transient || half cycle data acquisition || transient detection (20 µs)
Height
160 mm
Measurement Voltage
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Sampling Rate
1024 samples/cycle
Memory Capacity
2 GB
Number Of Outputs
4 digital || 2 form C relay output
Type Of Measurement
voltage sags and swells || current sags and swells || voltage || current || frequency || active and reactive power total || apparent power total || active and reactive power per phase || apparent power per phase || power factor total || power factor per phase || active and reactive energy || apparent energy || harmonic distorsion (I THD & U THD)
Communication Port Protocol
Modbus RTU 2400...115200 bps - 2-wire || ION 2400...115200 bps - 2-wire || DNP3 2400...115200 bps - 2-wire || Modbus TCP 10/100 Mbit/s || ION TCP 10/100 Mbit/s || DNP3 TCP 10/100 Mbit/s || IEC 61850 || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || DHCP || DNS || DLMS
Frequency Measurement Range
20-450 Hz
Communication Service
compliant reports || power quality summary || energy report || EcoStruxure Power Events Analysis || SMTP e-mail notification || SNMP
Ride-Through Time
100 ms 6 cycles at 60 Hz 120 V AC typical || 400 ms 24 cycles at 60 Hz 240 V AC typical || 1200 ms 72 cycles at 60 Hz 480 V AC typical
Port Ethernet
10/100BASE-TX 2 RJ45
Display Resolution
800 x 480 pixels
Power Consumption In Va
38 VA 480 V AC
Net Weight
1.5 kg
Tamperproof Of Settings
protected by sealable cover
Measurement Current
0.01-20 A
Electrical Insulation Class
class III EN/IEC 62052-11
Number Of Inputs
8 digital 30 V AC/60 V DC
Time Synchronisation Protocol
GPS || IRIG-B || NTP || SNTP || PTP
Measurement Accuracy
voltage +/- 0.1 % || current +/- 0.1 %
Ethernet Service
DHCP client || Device Profile Web Services (DPWS) || Rapid Scanning Tree Protocol (RSTP) || FTP/HTTP/HTTPS
Mounting Support
DIN rail meter device || door cut-out remote display
Communication Gateway
Ethernet/serial
Poles Description
3P + N + E
Data Recording
time stamping || min/max of instantaneous values || user-definable data logs || continuous logging or snapshot || trending/forecasting || event logs || alarm logs || configuration change || power outage || user login/logout || data logs || GPS synchronisation || sequence of event recording
Line Rated Current
1 A || 5 A
Cybersecurity
Syslog protocol support || robust security logs || port hardening || enable/disable communication ports || hardware metrology lock
Isolation Voltage
III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
voltage (impedance 5 MOhm) || external CT (impedance 0.3 mOhm)5 x
Web Services
viewing of captured waveform || web page || pass/fail report for IEEE 519 || pass/fail report for EN 50160 || ITIC (CBEMA) curve || SEMI curve || NEMA motor derating curve || alarm notification by e-mail || TLS 1.2 || push historical data via mail
Width
160 mm
Display Type
remote LCD display || colour touchscreen
Depth
135.3 mm
Accuracy Class
class 0.1S active energy IEC 62053-22 || class 0.1 active energy IEC 61557-12 || class 0.1 active energy ANSI C12.20 || class 0.5S reactive energy IEC 62053-24 || class 0.1 current IEC 61557-12 || class 0.1 voltage IEC 61557-12 || class 0.1 active power IEC 61557-12 || class 0.5 power factor IEC 61557-12
Maximum Power Consumption In Va
80 VA 480 V AC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1801009EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1801009EN
Eu Rohs Directive
Compliant with Exemptions

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
ANSI C12.20 || ANSI C37.90.1 || IEC 61000-4-15 || IEC 61000-4-30 || IEC 61010-1 || IEC 61326-1 || IEC 61557-12 || IEC 61850 || IEC 62052-11 || IEC 62052-31 || IEC 62053-22 || IEC 62053-23 || IEC 62053-24 || IEC 62586 || UL 61010-1
Degree Of Protection
UL type 12, front
Electromagnetic Compatibility
EMC immunity conforming to IEC 62052-11 || EMC immunity conforming to IEC 61326-1 || EMC immunity conforming to IEC 61000-6-5 || electrostatic discharge immunity test conforming to IEC 61000-4-2 || immunity to radiated fields conforming to IEC 61000-4-3 || immunity to fast transients conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || immunity to conducted disturbances conforming to IEC 61000-4-6 || immunity to magnetic fields at network frequency conforming to IEC 61000-4-8 || immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions class B conforming to EN 55032 || conducted and radiated emissions class B conforming to FCC part 15 || conducted and radiated emissions class B conforming to ICES-003 || surge withstand conforming to ANSI C37.90.1 || surge withstand conforming to IEEE C37.90.1
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 %
Quality Labels
ISO 9001 || ISO 14000
Ip Degree Of Protection
front IP65 || rear IP30
Operating Altitude
0...9842.52 ft (0...3000 m)
Installation Category
III

Specifications

Product Or Component Type
energy and power quality meter
Range
PowerLogic
Provided Equipment
remote display || remote display adapter || mounting instructions || Mounting Hardware
Device Application
power monitoring || WAGES metering || Net metering || medium voltage || high voltage
Device Short Name
ION92040
Metering Type
demand current I1, I2, I3, I4, I5 || peak demand currents || demand power P, Q, S || peak demand power PM, QM, SM || calculated active and reactive energy (+/- W.h, +/- VAR.h)