Descrizione

Attivo maturo
NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for non-linear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 100 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 18 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Interior is 27 inches tall and 10.44 inches wide. Lug connections will accept 6 AWG to 2/0 AWG aluminum wire. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
Country of Origin
MX
Part Number
NQ418L1
Tariff Code
8537109150
EAN
39121112
UPC
785901502128
UNSPSC
39121112
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Environment

Standards
UL || CSA

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1404019EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Height
27 in
Connections - Terminals
lug line AWG 6...AWG 2/0 aluminium || lug neutral AWG 6...AWG 2/0 aluminium
Tightening Torque
4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
[Iu] Rated Interrupted Current
10 kA || 22 kA || 65 kA
Number Of Spaces
18
Enclosure Nominal Height
26 in
Phase
3 phase
Enclosure Nominal Depth
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Line Rated Current
100 A
Width
10.44 in
Wiring Configuration
4-wire
Enclosure Nominal Width
20 in
[Ue] Rated Operational Voltage
240 V AC || 48 V DC

Specifications

Circuit Breaker Type
QOB || QOB-VH || QHB
Product Or Component Type
interiors
Material
aluminium
Load Center Type
main lugs

Documenti

Data Sheet

Scaricare