Schneider Electric
SC300A500FP
Hyde Park, Ultrasonic sensor, discrete, flat profile, 12 24 V DC
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Condizioni del prodotto:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo
Additional Information
- Part Number
- SC300A500FP
- UPC
- 785901234692
- UNSPSC
- 39122230
- Tariff Code
- 8536507000
- Country of Origin
- US
Specifications
- Type Of Sensing Window
- configurable
- Series Name
- Superprox +
- Type Of Output Signal
- discrete
- Range Of Product
- Hyde Park
- Supply Voltage Limits
- 10-28 V DC
- Product Specific Application
- discrete proximity
- Sensor Type
- ultrasonic sensor
- Electrical Connection
- cable, 3 m
- Sensor Design
- flat form
- Enclosure Material
- ULTEM
- Front Material
- glass epoxy
- Material
- plastic
- Device Short Name
- SC300
- [Us] Rated Supply Voltage
- 12...24 V DC overload and short-circuit protection
- Wiring Technique
- 4-wire
Contractual warranty
- Warranty
- 18 months
Complementary
- Repeat Accuracy
- 0.7 %
- Beam Angle
- 8 °
- Height
- 7.62 mm
- Minimum Size Of Detected Object
- cylinder diameter 2.5 mm - up to 1 mm sensing distance
- Maximum Switching Current
- 100 mA reverse polarity protection
- Transmission Frequency
- 500 kHz
- Width
- 19.05 mm
- Depth
- 7.62 mm
- Blind Zone
- 6.4-6.4 mm
- Length
- 33.02 mm
- Net Weight
- 0.12 kg
- Current Consumption
- 25 mA
- Maximum Differential Travel
- 0.7 mm
Offer Sustainability
- Eu Rohs Directive
- Not applicable, out of EU RoHS legal scope
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- UL
- Ambient Air Temperature For Operation
- -30-70 °C
- Resistance To Electromagnetic Fields
- 10 V/m level 3 IEC 61000-4-3
- Ambient Air Temperature For Storage
- -40-100 °C
- Relative Humidity
- 100-100 % without condensation
- Nema Degree Of Protection
- NEMA 4X indoor use only)
- Vibration Resistance
- +/-1 mm 10-55 Hz)IEC 60068-2-6
- Shock Resistance
- 30 gn in all 3 axes 11 ms IEC 60068-2-27
- Marking
- CE
- Resistance To Fast Transients
- 1 kV level 3 IEC 61000-4-4
- Ip Degree Of Protection
- IP67
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro