1 / 1
thumbnail

Descrizione

Attivo maturo
SE8300 Series room controllers are used for Low Voltage Fan Coil Unit control. The room controllers rated supply voltage range is 24 to 28V AC at 50 or 60Hz +/-15%. The rated current is 4A. The device consumption is up to 12VA. The room controller is colored white and is equiped with a communication port that uses BACnet MS/TP protocol and a PIR sensor. Its Room and Outdoor Air Temperature Display Range is between -40 and 50 oC. The measurement accuracy is +/- 0.5%. The temperature setting range is 12 to 37.5oC for cooling and 4.5 to 32 oC for heating. The room controller is equiped with 2 digital inputs, 5 analog inputs (5 to 10V), 4 analog outputs, and 5 digital outputs. The analog output voltage is 0 to 10V DC at < 5mA into > 2 kOhm resistance. The digital output rating is 28V AC 50 or 60 Hz, 0.3A, 1.5A inrush current. The product follows the following standards: IEC 61326-1: 2005, FCC part 15 subpart C, RSS 210 issue 8, FCC part 15 subpart B, ICES-003, EN 60950-1: 2006/A2, EN 60950-1: 2013, ETSI EN 301 489-1: v1.9.2. The product follows the directives: 2014/30/EU - electromagnetic compatibility, 2014/35/EU - low voltage directive, 2014/53/EU - radio equipment directive. The ambient air temperature for operation is between 0 and 50oC. The relative humidity for operating or storage is between 0 and 75% non condensing. The humidity reading range is 10 to 90% RH non-condensing.
Country of Origin
MX
Part Number
SE8350U0B11
Tariff Code
90321020
EAN
3606480770067
UPC
785901577126
UNSPSC
39121521
£413.60
net
£517.00
1
Metodi di pagamento:
Migliore offerta da:
GBFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Garanzia:
24 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Un totale di 32 Parts In-Stock da 5 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (4)

SE8350U0B11 product image
Schneider Electric

SE8350U0B11

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
24 mesi
1
€616.59
€554.93
net
SE8350U0B11 product image
Schneider Electric

SE8350U0B11

Condizione:
Nuove eccedenze
Disponibile:
10 pz.
Disponibile
Aggiornato il: 21-10-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
15-20 novembre a Regno Unito
1
£1,290.00
net
Spedizione da:
£99.00
SE8350U0B11 product image
Schneider Electric

SE8350U0B11

Condizione:
Nuove eccedenze
Disponibile:
10 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
SE8350U0B11 product image
Schneider Electric

SE8350U0B11

Condizione:
Nuove eccedenze
Disponibile:
10 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
FRFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€241.48

Specifications

Housing Colour
white
Ambient Air Temperature For Operation
0-50 °C
Height
120 mm
Calibration Certificate
1 Pt
Standards
EN/IEC 60730-1 || FCC part 15 Subpart B || ICES-003 || ETSI EN 300 328 || ETSI EN 301 489-1:v1.9.2 || FCC part 15 Subpart C || UL 60730-2-9 || ETSI EN 301 489-17:v2.2.1, 2012
Output Voltage
24 V AC relay output || 0...10 V DC analog output
Targeted Region
North America.
Product Or Component Type
room controller
Output Type
5 xrelay output || 4 xuniversal
Humidity Measurement Drift
Less Than 1 % Yearly
Product Name
SE8000 Series
Net Weight
340 g
Range
EcoStruxure Building Expert
Input Type
dry contact 2 || analog 5
Communication Port Protocol
BACnet MS/TP || Modbus RTU
Directives
2014/30/EU - electromagnetic compatibility || 2014/35/EU - low voltage directive || 2014/53/EU - radio equipment directive
Awg Gauge
AWG 24...AWG 18
Ambient Air Temperature For Storage
-30-50 °C
Output Current
1 A relay output || 3 A relay output inrush) || 0.3 A universal output || 1.5 A universal output inrush)
Input Voltage
0...10 V DC
Sensor Type
10 kOhm T2 NTC thermistor Temperature || space RH sensor Humidity || bulk polymer Humidity
Relative Humidity
0-95 %
Temperature Setting Range
12-37.5 °C cooling || 4.5-32 °C heating
Line Rated Current
4 A
Width
86 mm
Humidity Setting Range
30-95 %
Market Segment
Lodging/Hotel || small commercial || buildings || healthcare || non-critical buildings || office || residential || school
Temperature Resolution
0.1 °C
Depth
25 mm
Device Application
low voltage fan coil
Device Short Name
SE8300

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Eu Rohs Directive
Compliant with Exemptions

Complementary

Surface Finish
Matte
Surface Treatment
untreated