Attivo maturo
This control station with 2 push-buttons for 2 functions enables machine builders to easily add required control and signalling functionality on their machines Its schematic is clearly distinguishable thanks to clear colors and markings It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments
Country of Origin
FR
Part Number
XALD222H7
Tariff Code
8537109170
EAN
39122216
UNSPSC
39122216
Metodi di pagamento:
Migliore offerta da:
DEFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Environment

Product Certifications
UL Listed || CSA
Ik Degree Of Protection
IK03 EN 50102
Ambient Air Temperature For Operation
-40-70 °C
Standards
JIS C8201-5-1 || EN/IEC 60947-1 || EN/IEC 60947-5-4 || EN/IEC 60947-5-5 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-1 || JIS C8201-1
Shock Resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance
5 gn 12-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529 || IP67 || IP69 || IP69K
Ambient Air Temperature For Storage
-40-70 °C
Nema Degree Of Protection
NEMA 13 || NEMA 4X
Electrical Shock Protection Class
class II IEC 60536
Protective Treatment
TH

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1806010EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1806010EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Operating Force
3.8 N NO changing electrical state
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60947-5-1
Operating Travel
2.6 mm NO changing electrical state) || 4.3 mm total travel)
Contacts Material
silver alloy (Ag/Ni)
Positive Opening
without
[Ith] Conventional Free Air Thermal Current
10 A EN/IEC 60947-5-1
Cable Entry
2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
Colour Of Marking
black marking when white caps || white marking when green, red or black caps
Net Weight
0.233 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Resistance To High Pressure Washer
7000000 Pa 55 °C 0.1 m
Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Connections - Terminals
screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
[Ui] Rated Insulation Voltage
600 V 3)EN/IEC 60947-1
[Ie] Rated Operational Current
6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
Mechanical Durability
5000000 cycles
Electrical Reliability
λ < 10exp(-6) 5 V 1 mA EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA EN/IEC 60947-5-4
Tightening Torque
0.8-1.2 N.m EN/IEC 60947-1
Shape Of Screw Head
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm

Specifications

Control Station Application
two functions
Product Destination
for XB5 Ø 22 mm control and signalling units
Range Of Product
Harmony XALD
Colour Of Base Of Enclosure
light grey RAL 7035)
Control Station Composition
1 flush push-button, white 1 NO, black up arrow || 1 flush push-button, black 1 NO, white down arrow
Operators Description
white ''up arrow'' 1 NO - black ''down arrow'' 1 NO
Product Or Component Type
complete control station
Material
polycarbonate
Marking Location
marking on push-button
Operator Profile
2 flush push-buttons
Colour Of Cover
dark grey RAL 7016)
Contact Operation
slow-break
Device Short Name
XALD

Documenti

Data Sheet

Scaricare

Modelli CAD

traceparts
traceparts