1 / 1
thumbnail

Descrizione

Attivo maturo
This XCKT compact format (CENELEC EN 50047) limit switch has a metal end plunger and a plastic body. This limit switch has a double insulated Class II thermoplastic body, two electrical connection entries, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is IP66 and IK04 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.
Country of Origin
ID
Part Number
XCKT2110G11
Tariff Code
85365080
EAN
3389110319071
UNSPSC
39122213
Metodi di pagamento:
Migliore offerta da:
JOFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 27-08-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 4 Parts In-Stock da 3 Distributors
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (3)

XCKT2110G11 product image
Schneider Electric

XCKT2110G11

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 21-10-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
XCKT2110G11 product image
Schneider Electric

XCKT2110G11

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 21-10-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
XCKT2110G11 product image
Schneider Electric

XCKT2110G11

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo

Specifications

Movement Of Operating Head
linear
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return plunger metal
Sensor Design
compact form B CENELEC EN 50047
Product Or Component Type
limit switch
Head Material
zamak
Material
plastic
Head Type
plunger head
Type Of Approach
vertical approach, 1 direction
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Body Type
fixed
Contact Operation
snap action
Body Material
plastic
Device Short Name
XCKT
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
51-51 mm
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Short-Circuit Protection
10 A cartridge fuse gG
Minimum Actuation Speed
0.01 m/min
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Cable Entry
2 entries tapped for Pg 11 cable gland
Net Weight
0.1 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Switch Actuation
on end
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability
5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
45 N
Positive Opening
with
Contacts Insulation Form
Zb
Mechanical Durability
15000000 cycles
Maximum Actuation Speed
0.5 m/s
Minimum Force For Tripping
15 N
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width
58 mm
Depth
30 mm
Repeat Accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110603EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || CCC || UL
Ik Degree Of Protection
IK04 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN 60204-1 || UL 508 || IEC 60204-1 || CSA C22.2 No 14 || IEC 60947-5-1 || EN 60947-5-1
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class II IEC 61140 || class II NF C 20-030
Protective Treatment
TC