Schneider Electric

XCSLF353541M3

1 / 1
thumbnail

Descrizione

Attivo maturo
This XCSLF Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated slim Zamak body with a 19-pin M23 connector, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 2 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 500 000. Its IP65 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
ID
Part Number
XCSLF353541M3
Tariff Code
85365080
EAN
3606480465499
UNSPSC
39122213
Metodi di pagamento:
Migliore offerta da:
DEFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Specifications

[Us] Rated Supply Voltage
24 V - 15...10 %
Range Of Product
Telemecanique Safety switches XCS
Electrical Connection
male connector M23, 19 pins
Locking Options Description
with interlocking, locking by solenoid
Solenoid Contacts Type And Composition
1 NC + 2 NO slow-break, break before make)
Product Or Component Type
safety switch
Signalling Circuit Voltage
24 V
Component Name
XCSLF
Material
metal
Design
slim
Head Type
key operated turret head
Contacts Type And Composition
1 NC + 2 NO
Contact Operation
slow-break, break before make
Local Signalling
for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
Electromagnet Interlocking
by mushroom head push-button turn to release for escape release || locking on de-energisation and unlocking on energisation of solenoid
Cable Outer Diameter
7-13 mm
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Minimum Switching Current
10 mA at 20 °C
Height
225-225 mm
Short-Circuit Protection
4 A cartridge fuse gG (gl) || 6 A fast blow
Maximum Load Current
<= 15 A
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
4 A
Supply Voltage Type
AC/DC
Head Material
zamak
Signalling Circuit Type
AC/DC
Net Weight
1.1 kg
[Uimp] Rated Impulse Withstand Voltage
0.8 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
60 V 3)EN/IEC 60947-1 || 50 VUL 508 || 50 VCSA C22.2 No 14
Positive Opening
with NC contact
Load Factor
1
[Ie] Rated Operational Current
1.5 A 24 V, AC-15 EN/IEC 60947-5-1 || 0.22 A 24 V, DC-13 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
30000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
Width
44 mm
Depth
113 mm
Minimum Switching Voltage
17 V
Maximum Actuator Forcible Withdrawal Rtc
3000 N
Resistance To Mechanical Impact
9.6 J against the partition || 6.4 J without partition
Supply Frequency
50/60 Hz
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || TÜV || UL
Ambient Air Temperature For Operation
-25-60 °C
Standards
EN/IEC 60204-1 || UL 508 || CSA C22.2 No 14 || EN/IEC 62061 || EN/IEC 60947-5-1 || EN/ISO 13849-1 || EN 1088/ISO 14119
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP65
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC