1 / 1
thumbnail

Descrizione

Attivo maturo
This XCSPL Safety Limit Switch has a stainless steel turret head rotary elbowed flush lever with an operation contact to the right, a double insulated plastic enclosure and a Pg 11 cable gland entry. It has 2 normally closed slow break contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSPL771
Tariff Code
85365080
EAN
3389110866643
UNSPSC
39122213
Metodi di pagamento:
Migliore offerta da:
PLFornitore Automa.Net di fiducia
Disponibilità:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 3 Parts In-Stock da 2 Distributors
Consegna da:
PL
PL
DE
DE
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (1)

XCSPL771 product image
Schneider Electric

XCSPL771

Condizione:
Nuove eccedenze
Disponibile:
1 pz.
Disponibile
Aggiornato il: 08-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
Garanzia:
12 mesi
1
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo

Specifications

Contacts Type And Composition
1 NC + 1 NC
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped Pg 11
Clamping Connection Capacity
1 x 0.5...2 x 1.5 mm² with or without cable end
Product Or Component Type
guard switch
Component Name
XCSPL
Operator Direction Information
to right
Material
plastic
Head Type
turret head rotary lever
Insulation
double insulated
Contact Operation
slow-break
Type Of Operator
elbowed flush lever
Electrical Connection
terminal
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
88-88 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
[Ithe] Conventional Enclosed Thermal Current
10 A
Lever Material
stainless steel
Tripping Angle
5 °
Net Weight
0.095 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Positive Opening
with NC contact
Positive Opening Minimum Torque
0.25 N.m
Mechanical Durability
1000000 cycles
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
polyamide PA66 fibre glass impregnated
Contact Code Designation
A300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1
Width
103 mm
Depth
30 mm
Cable Outer Diameter
7-10 mm
Minimum Torque For Tripping
0.1 N.m
Maximum Resistance Across Terminals
30 mOhm EN/IEC 60947-5-4
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Circularity Profile
ENVEOLI110603EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || BG
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN 1088/ISO 14119 || EN/IEC 60947-5-4 || EN/IEC 60204-1 || UL 508 || EN/ISO 12100 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
50 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Protective Treatment
TC || TH