- Height
- 99 mm
- Mounting Support
- 35 mm symmetrical DIN rail
- Output Thermal Current
- 2 A for 1 output and 4 A for the other 2 outputs relay || 3.3 A for all 3 outputs relay simultaneously || 6 A for 1 output and 2 A for the other 2 outputs relay
- Power Consumption In W
- 5 W
- Minimum Output Voltage
- 17 V relay output
- Minimum Output Current
- 10 mA relay output
- [Ith] Conventional Free Air Thermal Current
- 20 A
- Associated Fuse Rating
- 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 || 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
- Net Weight
- 0.32 kg
- Number Of Additional Circuits
- 3 solid state outputs
- [Ui] Rated Insulation Voltage
- 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
- Local Signalling
- 12 LEDs
- Maximum Line Resistance
- 100 Ohm <2000 m
- Input Protection Type
- internal, electronic
- Width
- 45 mm
- Number Of Safety Circuits
- 3 NO relays per function (6 NO total), volt-free
- Depth
- 114 mm
- Synchronisation Time Between Inputs
- 0.5 s 13) || unlimited 8) || 1.5 s 14) || 1.5 s 15) || 1.5 s 5) || 1.5 s 6) || 1.5 s 9) || unlimited 3) || unlimited 4) || unlimited 7)
- [Uc] Control Circuit Voltage
- 24 V
- Function Of Module
- 0 functions disabled (factory setting) || 3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 9 guard monitoring for injection presses and blowing machines, category 4 || 1 emergency stop monitoring 1-channel wiring, category 2 || 10 enabling grip switch monitoring (3-position switch), category 4 || 11 sensing mat and edges monitoring, category 3 || 12 sensing mat and edges monitoring, category 3 || 13 relay output safety light curtain monitoring, category 4 || 14 coded magnetic switch monitoring, category 4 || 15 coded magnetic switch monitoring, category 4 || 2 emergency stop monitoring 1-channel wiring, category 2
- Breaking Capacity
- 20 mA 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
- Maximum Response Time On Input Open
- 30 ms
- Breaking Capacity
- 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output