This product is part of the XR range, an offer of limit switches. This limit switch is a device that converts a mechanical motion into an electrical control signal. It has 6 changeover, snap action contacts. The limit switch has a drive shaft, end fittings with sprocket key and washer operator. It is a limit switch with a rated operating current of 3A at 240V AC and 0.27A at 250V DC. It is furnished with screw clamp terminals for electrical connection. It is an IP54 rated product. This limit switch is made of sheet steel. It weighs 12kg. It is suitable for the specific applications such as hoisting, mining, minerals and metals or belt conveying. This limit switch meets EN/IEC 60947-5-1 standards. Wide offer of robust rotary limit switches which connect directly to rotating shafts for medium to heavy duty applications. Special format limit switches for severe environments.- Country of Origin
- FR
- Part Number
- XR2AB06K20
- Tariff Code
- 85365080
- EAN
- 3389110600711
- UNSPSC
- 39122213
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Specifications
- Range Of Product
- XR and XF
- Maximum Revolution Speed
- 250 rpm input drive shaft
- Type Of Operator
- drive shaft, end fittings with sprocket key and washer
- Product Or Component Type
- single-stage heavy duty screw limit switch
- Product Specific Application
- position control of moving parts of hoisting or materials handling equipment || liquid level control in pumping systems
- Material
- sheet steel enclosure
- Theoretical Number Of Turns
- 20 input drive shaft
- Device Short Name
- XR2
- Number Of Poles
- 1
Contractual warranty
- Warranty
- 18 months
Complementary
- Operating Finger Radius
- 40 mm
- Length Of Developed Helical Travel
- 4 mm
- Maximum Number Of Turns
- 6 threaded shaft
- Repeat Accuracy
- 0.02 % on the tripping point
- Maximum Resistance Across Terminals
- 25 MOhm
- Actual Number Of Turns
- 21.3 input drive shaft)
- Cable Entry
- removable gland plate
- Short-Circuit Protection
- 10 A cartridge fuse gG
- Net Weight
- 12 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-1
- Threaded Shaft Screw Pitch
- 4 mm
- Contacts Type And Composition
- 6 C/O
- Electrical Durability
- 10000000 cycles AC-15 50/60 Hz inductive 12 V, 70 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 127 V, 270 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 220 V, 290 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 24 V, 120 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 380 V, 300 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 48 V, 180 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz inductive 500 V, 300 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 12 V, 45 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 127 V, 180 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 220 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 24 V, 75 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 380 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 48 V, 120 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles AC-15 50/60 Hz resistive 500 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 12 V, 100 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 127 V, 1050 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 220 V, 1150 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 24 V, 220 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 380 V, 1150 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 48 V, 480 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz inductive 500 V, 1200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 12 V, 100 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 127 V, 700 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 220 V, 750 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 24 V, 200 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 380 V, 800 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 48 V, 400 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles AC-15 50/60 Hz resistive 500 V, 800 VA 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 110 V, 80 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 220 V, 60 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 24 V, 90 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 440 V, 33 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 inductive 48 V, 85 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 110 V, 30 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 12 V, 45 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 220 V, 20 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 24 V, 40 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 440 V, 7.5 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 10000000 cycles DC-13 resistive 48 V, 35 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 110 V, 110 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 220 V, 95 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 24 V, 140 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 440 V, 65 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 inductive 48 V, 130 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 110 V, 95 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 12 V, 100 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 220 V, 80 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 24 V, 120 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 440 V, 45 W 3600 cyc/h 0.5 EN/IEC 60947-5-1 || 3000000 cycles DC-13 resistive 48 V, 110 W 3600 cyc/h 0.5 EN/IEC 60947-5-1
- [Ui] Rated Insulation Voltage
- 500 V EN/IEC 60947-1 || 600 V CSA C22.2 No 14
- Connections - Terminals
- screw clamp terminals, 2 x 1.5 mm² with or without cable end || screw clamp terminals, 2 x 2.5 mm² without cable end
- [Ie] Rated Operational Current
- A300, AC-15, Ue = 240 V, Ie = 3 A EN/IEC 60947-5-1 || Q300, DC-13, Ue = 250 V, Ie = 0.27 A EN/IEC 60947-5-1
- Contact Operation
- snap action
- Mechanical Durability
- 10000000 cycles
- Differential Snap Over Angle
- 30 ° contact actuators measured at finger
- Number Of Teeth
- 26 pinion A) || 26 pinion C) || 49 pinion B) || 49 pinion D)
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
Offer Sustainability
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Not applicable, out of EU RoHS legal scope
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/IEC 60947-5-1
- Shock Resistance
- 50 gn 11 ms
- Vibration Resistance
- > 5 gn 10-55 Hz)
- Ip Degree Of Protection
- IP54 EN/IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Protective Treatment
- TC
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro