Photoelectric sensors XU, XUK, emitter, 24...240VAC/DC, cable 2 m
XUK2ARCNL2T
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
219,30 zł
1
Metodi di pagamento:
Un totale di 12 Parts In-Stock da 13 Distributors
Offerta con tempi di consegna del produttore
Spedizione in:1 - 2 Molti giorni lavorativi
Miglior prezzo:
Invia una richiesta di prezzo

Additional Information

Part Number
XUK2ARCNL2T
UNSPSC
39121528
Tariff Code
8541498000
Country of Origin
ID

Specifications

Electrical Connection
cable
Range Of Product
Telemecanique Photoelectric sensors XU
Cable Length
2 m
Emission
infrared thru beam
Sensor Name
XUK
Material
plastic
Wiring Technique
2-wire
Series Name
general purpose single mode
Detection System
thru beam
Sensor Design
compact 50 x 50
Supply Circuit Type
AC/DC
Electronic Sensor Type
photo-electric sensor transmitter
[Sn] Nominal Sensing Distance
30-30 m thru beam need a receiver

Contractual warranty

Warranty
18 months

Complementary

Current Consumption
<= 35 mA no-load
Height
50 mm
Switching Frequency
<= 250 Hz
Maximum Delay Response
25 ms
Status Led
1 LED green)supply on
Setting-Up
without sensitivity adjustment
Lens Material
PMMA
Maximum Voltage Drop
<1.5 V closed state)
Add On Input
test by emission breaking
Maximum Delay Recovery
25 ms
Maximum Delay First Up
60 ms
Maximum Sensing Distance
45 m thru beam
Supply Voltage Limits
20-264 V AC/DC
Switching Capacity In Ma
3 A cos φ = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V)
Wire Insulation Material
PVC
Enclosure Material
PBT
Width
18 mm
Depth
50 mm
[Us] Rated Supply Voltage
24...240 V AC/DC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111232EN
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI111207EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || CE || UL
Ambient Air Temperature For Operation
-25-55 °C
Vibration Resistance
7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
Shock Resistance
30 gn 11 ms) IEC 60068-2-27
Ambient Air Temperature For Storage
-40-70 °C
Ip Degree Of Protection
IP65 double insulation IEC 60529