Schneider Electric

XUVE04M3KSNM8

Photoelectric sensors XU, photoelec sensor label fork 40x3, 12...24 V DC, PNP/NPN NO/NC connect M8
XUVE04M3KSNM8
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 1 Part In-Stock da 10 Distributors

Specifications

Passage Width
3 mm
Type Of Setting
without
Electrical Connection
1 male connector M8, 4 pins
Discrete Output Type
PNP and NPN
Discrete Output Function
2 NO/NC programmable
Range Of Product
Telemecanique Photoelectric sensors XU
Passage Depth
40 mm
Emission
infrared
Sensor Name
XUV
Material
PA (polyamide) 12
Wiring Technique
4-wire
Series Name
Application packaging
Product Specific Application
detection of labels
Detection System
thru beam
Sensor Design
fork
Supply Circuit Type
DC
Electronic Sensor Type
photo-electric sensor
[Sn] Nominal Sensing Distance
3-3 mm thru beam

Contractual warranty

Warranty
18 months

Complementary

Height
25 mm
Switching Frequency
<= 10 kHz
Maximum Delay Response
0.1 ms
Type Of Output Signal
discrete
Status Led
output state 1 LED yellow) || adjustment mode and keypad locking 1 LED red)
Setting-Up
numeric potentiometer
Lens Material
PC
Maximum Voltage Drop
<2 V closed state)
Net Weight
0.035 kg
Accuracy
+/- 0.05 mm 150 m/min
Minimum Distance Between Labels
2 mm
Maximum Delay Recovery
0.1 ms
Maximum Delay First Up
30 ms
Supply Voltage Limits
10-30 V DC
Minimum Label Length
2 mm
Switching Capacity In Ma
<= 100 mA overload and short-circuit protection)
Enclosure Material
Polyamide
Width
10 mm
Output Type
solid state
Depth
64 mm
Maximum Passing Speed Of Object
200 m/min
[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CE || cULus
Ambient Air Temperature For Operation
-20-60 °C
Vibration Resistance
7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
Shock Resistance
30 gn 11 ms) IEC 60068-2-27
Ambient Air Temperature For Storage
-30-80 °C
Ip Degree Of Protection
IP65 IEC 60529

Documenti

Data Sheet

Scaricare

Prodotti correlati