Additional Information

Part Number
XY2CE1C296
UNSPSC
39122239
Country of Origin
MA

Specifications

Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Product Or Component Type
latching emergency stop rope pull switch
Housing Colour
red RAL 3000
Overvoltage Category
class I EN/IEC 61140 || class I NF C 20-030
Device Short Name
XY2CE

Contractual warranty

Warranty
18 months

Complementary

Reset
by key-release push-button
Number Of Cables
1
Terminals Description Iso N°1
(11-22)NC || (21-22)NC
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
Positive Opening
with EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current
10 A
Marking
CE
Local Signalling
without pilot light
Net Weight
1.47 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Trigger Cable Maximum Length
70 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Distance Between Cable Supports
5-5 m
Mechanical Durability
60000 cycles
Cable Entry Number
3
Compatibility Code
XY2CE
Body Material
zamak
Trigger Cable Anchor Point
RH side
Safety Reliability Data
B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Material
stainless steel
Tightening Torque
0.8-1.2 N.m
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111159EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-40-70 °C
Standards
EN/IEC 60947-5-5 || machinery directive 2006/42/EC || UL 508 || CSA C22.2 No 14 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || work equipment directive 2009/104/EC || EN/ISO 13850
Product Certifications
UL category NISD emergency stop devices || CSA || CCC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-300 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP65 IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC