Schneider Electric
XY2CE4A010H7
1 / 1
Descrizione
Attivo maturo
This product is part of the XY2C range, an offer of emergency stop rope pull switches. It is ideal for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. It is suitable for applications such as woodworking machines, shears, conveyor systems, printing machines, textile machines etc. This emergency stop rope pull switch has 1 normally closed and 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.27A at 250V AC, 3A at 240V AC and a conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection. Switch has three 1/2 inch NPT tapped conduit entries. The trigger cable anchor point at left hand side. It offers long mechanical durability which is about 60000 operating cycles. It is an IP66 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 7.68 inches (Width) x 4.13 inches (Depth) x 5.59 inchers (Height) and weighs 3.20 lbs. This product meets UL508, CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, machinery directive 2006/42/EC and work equipment directive 2009/104/EC standards. This product is certified by UL, CSA and CCC. The XY2 line of switches come in a robust metal enclosure so they can be used in severe environments and they conform to EN/ISO 13850 and EN/IEC 60947-5-5. XY2 range emergency stop rope pull switch is intended for all machines requiring stopping of a dangerous movement in the immediate vicinity of the machine.- Country of Origin
- MA
- Part Number
- XY2CE4A010H7
- Tariff Code
- 8536509065
- EAN
- 39122213
- UNSPSC
- 39122213
Metodi di pagamento:
- Migliore offerta da:
- Fornitore Automa.Net di fiducia
- Disponibilità:
- 1 pz.DisponibileAggiornato il: 12-11-2024
- Garanzia:
- 12 mesi
- Consegna stimata:
- Su richiesta
- Condizione:
- Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia
Specifications
- Housing Colour
- blue
- Range Of Product
- Telemecanique Emergency stop rope pull switches XY2C
- Overvoltage Category
- class I EN/IEC 61140 || class I NF C 20-030
- Product Or Component Type
- latching emergency stop rope pull switch
- Device Short Name
- XY2CE
Contractual warranty
- Warranty
- 18 months
Complementary
- Trigger Cable Maximum Length
- 50 m
- Connections - Terminals
- screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
- Reset
- without
- Contacts Type And Composition
- 1 NC + 1 NO
- Number Of Cables
- 1
- [Ui] Rated Insulation Voltage
- 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
- Short-Circuit Protection
- 10 A cartridge fuse gG EN/IEC 60269
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
- Contact Operation
- snap action
- Distance Between Cable Supports
- 5-5 m
- Mechanical Durability
- 60000 cycles
- Positive Opening
- with EN/IEC 60947-5-1
- Cable Entry Number
- 3 tapped entry Pg 13.5 cable gland
- Compatibility Code
- XY2CE
- Body Material
- zamak
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Trigger Cable Anchor Point
- LH side
- Marking
- CE
- Cover Material
- stainless steel
- Local Signalling
- without pilot light
- Tightening Torque
- 0.8-1.2 N.m
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-1
- Maximum Resistance Across Terminals
- 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111159EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Ambient Air Temperature For Storage
- -40-70 °C
- Standards
- EN/IEC 60947-5-1
- Product Certifications
- CSA
- Shock Resistance
- 50 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 10 gn 10-300 Hz)EN/IEC 60068-2-6
- Protective Treatment
- TC
- Ip Degree Of Protection
- IP66 IEC 60529
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro