Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 1NC+1 NO, mushroom head pushbutton
XY2CH13350
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
$510.30
1
Metodi di pagamento:
Un totale di 1 Part In-Stock da 9 Distributors
Offerta con tempi di consegna del produttore
Spedizione in:1 - 2 Molti giorni lavorativi
Miglior prezzo:
Invia una richiesta di prezzo

Additional Information

Part Number
XY2CH13350
UNSPSC
39122205
Tariff Code
8536509065
Country of Origin
MA

Specifications

Housing Colour
red RAL 3000
Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Overvoltage Category
class I EN/IEC 61140 || class I NF C 20-030
Product Or Component Type
latching emergency stop rope pull switch
Device Short Name
XY2CH

Contractual warranty

Warranty
18 months

Complementary

Trigger Cable Maximum Length
30 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Reset
by mushroom head push-button
Contacts Type And Composition
1 NC + 1 NO
Number Of Cables
1
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
5-5 m
Mechanical Durability
800000 cycles
Positive Opening
with EN/IEC 60947-5-1
Cable Entry Number
3 tapped entry Pg 13.5 cable gland
Compatibility Code
XY2CH
Body Material
zamak
[Ithe] Conventional Enclosed Thermal Current
10 A
Trigger Cable Anchor Point
RH or LH side
Safety Reliability Data
B10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking
CE
Cover Material
stainless steel
Local Signalling
without pilot light
Net Weight
0.9 kg
Tightening Torque
0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111159EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60204-1 || work equipment directive 2009/104/EC || EN/IEC 60947-5-1 || EN/ISO 13850 || machinery directive 2006/42/EC || EN/IEC 60947-5-5
Product Certifications
CCC category NISD emergency stop devices || UL
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP65 IEC 60529

Documenti

Data Sheet

Scaricare

Prodotti correlati