General Purpose Ventilated Transformers - PN

1 / 1
SolaHD E2H30S General Purpose Ventilated Transformers - PN — Ingranaggi e riduttori
Immagine di catalogo del produttore

Descrizione del prodotto

The General Purpose Ventilated Transformers, classified as isolation transformers, are designed for applications requiring reliable voltage transformation. Operating within a 600 Volt Class, these transformers are available in both single-phase and three-phase configurations, providing versatility for indoor and outdoor installations.

In terms of specifications, the single-phase models support primary voltages of 240 x 480 volts with secondary outputs of 120/240 volts, available in capacities ranging from 15 kVA to 100 kVA. Additionally, for three-phase applications, options include configurations with primary voltages of 480 volts Δ and 208/120 volts secondary, covering capacities from 15 kVA to 500 kVA. The transformers can accommodate various voltage combinations, including 480Y/277 and 208Y/120, ensuring adaptability to different circuit configurations.

With a temperature rise rated at +150°C and options for aluminum or copper windings, these transformers are engineered to meet demanding operational conditions. Designation Code: E2H30S

  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
Invia la richiesta
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Specifiche tecniche

Marchio
SolaHD
Group 1
Single Phase. 240 x 480 Volt Primary, 120/240 Secondary. 15, 25, 37.5, 50, 75, 100, 167 kVA
Group 2
Single Phase. 120/208/240/277 Volt Primary, 120/240 Secondary. 15, 25 kVA.
Group A
Three Phase. 480 Volt ∆ Primary, 208/120 Secondary. 15, 30, 45, 75, 112.5, 150, 225, 300, 500 kVA
Group B
Three Phase. 480 Volt ∆ Primary, 240 Volt ∆, Secondary with reduced capacity center tap. 15, 30, 45, 75, 112.5, 150, 225, 300, 500 kVA
Group C
Three Phase. 480 Volt ∆ Primary, 480Y/277 Secondary. 15, 30, 45, 75, 112.5, 150, 225, 300, 500 kVA
Group D
Three Phase. 208 Volt ∆ Primary, 480Y/277 Secondary. 15, 30, 45, 75, 112.5, 150 kVA

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni

Documenti

Scheda tecnica

Scheda tecnica per SolaHD E2H30S, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti correlati

GBX060009K Schneider Electric
GBX060009K
Schneider Electric
This planetary gearbox features straight teeth, designed for adapting motor speeds and torques, with a 60mm external diameter and a reduction ratio of 9:1.
GBX080016K Schneider Electric
GBX080016K
Schneider Electric
This planetary gearbox features straight teeth and is designed for adapting motor speeds and torques, with a reduction ratio of 16:1 and a continuous output torque of 120N.m.
3VA2040-6JP36-0AA0 Siemens
3VA2040-6JP36-0AA0
Siemens
3VA20 IEC molded case circuit breaker with electronic trip unit, 40A 3-pole configuration and class H breaking capacity of 85kA at 415V.
3VA5145-6EC41-0AA0 Siemens
3VA5145-6EC41-0AA0
Siemens
4-pole circuit breaker with a rated current of 45A and a breaking capacity of 65kA at 480V, featuring a TM230 thermal-magnetic trip unit.
3VA2010-7HL46-0AA0 Siemens
3VA2010-7HL46-0AA0
Siemens
The 3VA20 4-pole circuit breaker features a rated current of 100A and a breaking capacity of 110kA at 415V, designed for line protection with an ETU320 electronic trip unit.
3VA2225-6HM42-0AA0 Siemens
3VA2225-6HM42-0AA0
Siemens
4-pole circuit breaker with a rated current of 250A and a short-circuit breaking capacity of 85kA at 415V, designed for line protection with overload and ground-fault protection.
HBL2816 Hubbell
HBL2816
Hubbell
This twist-lock flanged receptacle supports a 30A, 3-phase 120/208V AC connection with a 4-pole, 5-wire grounding configuration.
1SAM201906R1115 ABB
1SAM201906R1115
ABB
The PS1-5-1-65 is a 3-phase busbar designed for connecting up to 5 MS132 or MS116 manual motor starters with 1 lateral auxiliary contact, featuring a rated current of 65 A.
2CCS894001R0825 ABB
2CCS894001R0825
ABB
The S804N-B100 is a 4-pole circuit breaker with a B-characteristic and a rated current of 100 A.
1SDA071193R1 ABB
1SDA071193R1
ABB
The E4.2N 4000 is a fixed three-pole air circuit breaker equipped with solid-state release and horizontal rear terminals, designed for AC applications.
3VA1163-3GD42-0AA0 Siemens
3VA1163-3GD42-0AA0
Siemens
4-pole circuit breaker with thermal-magnetic trip unit, rated at 63A and a breaking capacity of 25kA at 415V, designed for line protection.
ATV630D22N4Z Schneider Electric
ATV630D22N4Z
Schneider Electric
The Variable Speed Drive ATV630 is designed to control 3-phase synchronous and asynchronous motors, supporting power ratings up to 22 kW.

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia