TE Connectivity
T92P7D52-24
1 / 1
- Part Number
- T92P7D52-24
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Packaging Features
- Packaging Method
- Tray/Box
Dimensions
- Length Class (Mechanical) (mm)
- 50 – 60
- Insulation Clearance Class
- 5 – 8mm
- Height
- 51.1 mm [ 2.012 in ]
- Width Class (Mechanical) (mm)
- 30 – 40
- Height Class (Mechanical) (mm)
- >50
- Length
- 54.2 mm [ 2.134 in ]
- Width
- 36.3 mm [ 1.429 in ]
- Insulation Clearance Between Contact and Coil
- 8 mm [ .315 in ]
Mechanical Attachment
- Mounting Type
- Flange Mount, Panel Mount
Usage Conditions
- Environmental Ambient Temperature Class
- 50 – 70°C
- Environmental Category of Protection
- RTI
- Environmental Ambient Temperature (Max)
- 65 °C [ 149 °F ]
Contact Features
- Terminal Type
- Screw Terminals
- Contact Number of Poles
- 2
- Contact Arrangement
- 2 Form A (NO)
- Contact Current Rating (A)
- 30
- Contact Material
- AgCdO
- Contact Current Class
- 20 – 30 A, Greater Than 16A
Body Features
- Insulation Special Features
- 6000V Initial Surge Withstand Voltage between Contacts and Coil
- Weight
- 86 g [ 3.034 oz ]
Product Type Features
- Product Type
- Relay
- Relay Type
- T92 Series 2-Pole 30A PCB
Electrical Characteristics
- Contact Limiting Breaking Current (A)
- 30
- Contact Limiting Making Current (A)
- 30
- Coil Resistance (Ω)
- 350
- Insulation Initial Dielectric Between Coil/Contact Class
- 3500 – 4000 V
- Contact Limiting Continuous Current (A)
- 30
- Contact Limiting Short-Time Current (A)
- 30
- Coil Special Features
- UL Coil Insulation Class F
- Coil Power Rating Class
- >1.5W
- Coil Magnetic System
- Monostable, DC
- Contact Switching Voltage (Max) (VAC)
- 600
- Insulation Initial Resistance (MΩ)
- 1000000
- Coil Voltage Rating (VDC)
- 24
- Coil Power Rating (DC) (mW)
- 1700
- Insulation Creepage Between Contact and Coil
- 9.5 mm [ .374 in ]
- Insulation Creepage Class
- >8mm
- Contact Voltage Rating (VAC)
- 277
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1500
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 4000
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 2000
- Contact Switching Load (Min)
- 500mA @ 12V
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro