Wago

2022-162

1 / 1
thumbnail
Part Number
2022-162
Tariff Code
85366990990
UPC
4050821243328
ETIM
Group Code : EG000012
Group Description : Terminal blocks
Class Description : Single- and multi-pole terminal strip
Class Code : EC001284
Version : 7
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Ratings Per Iec/En

Ratings per
IEC/EN 61984
Nominal voltage (III/3)
690 V
Rated impulse voltage (III/3)
6 kV
Rated current
24 A
Current at conductor cross-section (max.) mm²
32 A
Legend (ratings)
(III / 3) ≙ Overvoltage category III / Pollution degree 3

Environmental Requirements

Processing temperature
-35 … +85 °C
Continuous operating temperature
-60 … +105 °C

Plug-In Connection

Contact type (pluggable connector)
Female connector/socket
Connector (connection type)
For conductor
Mismating protection
No
Plugging without loss of pin spacing
Yes

Physical Data

Width
5.2 mm / 0.205 inches
Height
40.5 mm / 1.594 inches
Depth
22.4 mm / 0.882 inches

Material Data

Note (material data)
<a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
Color
Orange
Material group
I
Insulation material
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.060 MJ
Weight
3.415 g

Mechanical Data

Variable coding
Yes
Marking level
Side marking
Anti-rotation protection
Yes

Specifications

Product Group Code
0018

Commercial Data

Packaging type
Box
Country of origin
CN
GTIN
4050821243328
Customs tariff number
85366990990

Notes

Safety information
According to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.

Ratings Per Csa

Approvals per
CSA 22.2 No 158
Rated voltage CSA (Use Group C)
600 V
Rated current CSA (Use Group C)
20 A

Connection 1

Connection technology
Push-in CAGE CLAMP®
Actuation type
Operating tool
Connectable conductor materials
Copper
Nominal cross-section
2.5 mm²
Solid conductor
0.25 … 4 mm² / 22 … 12 AWG
Solid conductor; push-in termination
0.75 … 4 mm² / 18 … 12 AWG
Fine-stranded conductor
0.25 … 4 mm² / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule
0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination
1 … 2.5 mm² / 18 … 14 AWG
Note (conductor cross-section)
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length
10 … 12 mm / 0.39 … 0.47 inches
Pole number
1
Wiring direction
Front-entry wiring

Ratings Per Ul 1059

Approvals per
UL 1059
Rated voltage UL (Use Group B)
600 V
Rated current UL (Use Group B)
20 A
Rated voltage UL (Use Group C)
600 V
Rated current UL (Use Group C)
20 A

Prodotti correlati