Wago

750-495/000-002

3-Phase Power Measurement; 690 VAC Rogowski coils
750-495/000-002
750-495/000-002
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 51 Parts In-Stock da 10 Distributors

Additional Information

Part Number
750-495/000-002
UPC
4050821841593
Tariff Code
85389099990
ETIM
Group Code : EG000024
Group Description : PLC's
Class Description : Fieldbus, decentr. periphery - function-/technology module
Class Code : EC001601
Version : 7

Environmental Requirements

Ambient temperature (operation)
0 … +55 °C
Ambient temperature (storage)
-25 … +85 °C
Protection type
IP20
Pollution degree
2
Operating altitude
0 … 2000 m / 0 … 6562 ft
Mounting position
Horizontal (standing/lying); vertical
Relative humidity (without condensation)
95 %
Vibration resistance
4g per IEC 60068-2-6
Shock resistance
15g per IEC 60068-2-27
EMC immunity to interference
Per EN 61000-6-2
EMC emission of interference
Per EN 61000-6-3
Exposure to pollutants
Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity 75 %
10 ppm
Permissible SO2 contaminant concentration at a relative humidity 75 %
25 ppm

Connection Data

Connection technology: inputs/outputs
16 x CAGE CLAMP®
Connection type 1
Inputs/outputs
Solid conductor
0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor
0.08 … 2.5 mm² / 28 … 14 AWG
Strip length
8 … 9 mm / 0.31 … 0.35 inches

Physical Data

Width
24 mm / 0.945 inches
Height
100 mm / 3.937 inches
Depth
67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail
60.6 mm / 2.386 inches

Material Data

Housing material
Polycarbonate; polyamide 6.6
Fire load
2.001 MJ
Weight
98.111 g
Conformity marking
CE

Technical Data

Number of measurement inputs
7 (3 Spannungsmesseingänge, 4 differentielle Strommesseingänge)
Signal type
Power measurement
Signal form
Any periodic signals (considering the threshold frequencies)
Resolution [bit]
24 bits
Data width
2 x 128-bit data; 2 x 64-bit control/status
Voltage path input resistance (typ.)
1429 kΩ
Current path input resistance (typ.)
44 kΩ
Reference for measurement error
AC current/voltage
Measurement error (reference temperature)
25 °C
Measurement error, deviation (max.) from the upper-range value
0.5 %
Measurement current (max.)
Rogowski Coils RT500/RT2000
Measurement cycle time
Adjustable for arithmetic mean value, Min_Max_Values
Frequency range (mains frequency)
45 … 65 Hz
Frequency range (harmonics analysis)
0 … 3300 Hz
Limit frequency
15.9 kHz
Rated voltage
VLN = 400 VAC; VLL = 690 VAC
Calculated values
Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
Measurement components
Evaluating
Measurement method
True RMS measurement
Configuration options
WAGO-I/O-CHECK || CODESYS Library || e!COCKPIT
Supply voltage (system)
5 VDC; via data contacts
Current consumption (5 V system supply)
100 mA
Isolation
6 kV system/field
Rated surge voltage
6 kV
Indicators
LED (A) green: Communication; LED (B-G) red: Error L1, Display: Override in current measurement path, Display: Undervoltage in voltage measurement path, Error L2, Error L3, Display: Override in voltage measurement path; LED (H) yellow: Interchange in phase sequence L1-L2-L3

Mechanical Data

Mounting type
DIN-35 rail

Specifications

Product Group Code
0015

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4050821841593
Customs tariff number
85389099990

Prodotti correlati