Additional Information
- Part Number
- 1531180000
Rated Data Acc. To Ul 1059
- Institute (UR)
- UR
- Certificate No. (UR)
- E60693
- Rated voltage (Use group B / UL 1059)
- 50 V
- Rated voltage (Use group D / UL 1059)
- 50 V
- Rated current (Use group B / UL 1059)
- 5 A
- Rated current (Use group D / UL 1059)
- 5 A
- Wire cross-section, AWG, min.
- AWG 24
- Wire cross-section, AWG, max.
- AWG 16
- Reference to approval values
- Specifications are maximum values, details - see approval certificate.
Approvals
- Approvals
- EAC, UR
- ROHS
- Conform
- UL File Number Search
- E60693
Dimensions And Weights
- Width
- 42.3 mm
- Width (inches)
- 1.665 inch
- Height
- 14.5 mm
- Height (inches)
- 0.571 inch
- Depth
- 29.1 mm
- Depth (inches)
- 1.146 inch
- Net weight
- 5.705 g
Rated Data Acc. To Iec
- Tested acc. to standard
- IEC 60664-1, IEC 61984
- Rated current, min. number of poles (Tu=20°C)
- 2.2 A
- Rated current, max. number of poles (Tu=20°C)
- 2 A
- Rated current, min. number of poles (Tu=40°C)
- 2.2 A
- Rated current, max. number of poles (Tu=40°C)
- 2 A
- Rated voltage for surge voltage class / pollution degree II/2
- 200 V
- Rated voltage for surge voltage class / pollution degree III/2
- 160 V
- Rated voltage for surge voltage class / pollution degree III/3
- 50 V
- Rated impulse voltage for surge voltage class/ pollution degree II/2
- 2.5 kV
- Rated impulse voltage for surge voltage class/ pollution degree III/2
- 2.5 kV
- Rated impulse voltage for surge voltage class/ contamination degree III/3
- 0.8 kV
- Short-time withstand current resistance
- 3 x 1s with 120 A
Material Data
- Insulating material
- PBT
- Colour
- black
- Colour of operational elements
- grey, blue, red
- Material of operational elements
- PBT
- Colour chart (similar)
- RAL 9011
- Insulating material group
- IIIa
- Comparative Tracking Index (CTI)
- ≥ 200
- Insulation strength
- ≥ 108 Ω
- UL 94 flammability rating
- V-0
- GWFI
- 960 °C
- Contact base material
- Copper alloy
- Contact material
- Copper alloy
- Contact surface
- tinned
- Storage temperature, min.
- -25 °C
- Storage temperature, max.
- 55 °C
- Max. relative humidity during storage
- 80 %
- Operating temperature, min.
- -50 °C
- Operating temperature, max.
- 75 °C
- Temperature range, installation, min.
- -30 °C
- Temperature range, installation, max.
- 75 °C
Classifications
- ETIM 6.0
- EC002638
- ETIM 7.0
- EC002638
- EClass 9.0
- 27-44-03-09
- EClass 9.1
- 27-44-03-09
- EClass 10.0
- 27-44-03-09
System Parameters
- Product family
- OMNIMATE Signal - series BL/SL 3.50
- Type of connection
- Field connection
- Wire connection method
- PUSH IN, Tension-clamp connection
- Pitch in mm (P)
- 3.5 mm
- Pitch in inches (P)
- 0.138 inch
- Conductor outlet direction
- 180°
- Number of poles
- 10
- L1 in mm
- 31.5 mm
- L1 in inches
- 1.24 inch
- Pin series quantity
- 1
- Rated cross-section
- 1 mm²
- Touch-safe protection acc. to DIN VDE 57 106
- Safe from finger touch
- Touch-safe protection acc. to DIN VDE 0470
- IP 20
- Can be coded
- Yes
- Stripping length
- 8 mm
- Screwdriver blade
- 0.4 x 2.5
- Screwdriver blade standard
- DIN 5264
- Plugging force/pole, max.
- 6 N
- Pulling force/pole, max.
- 6 N
Packing
- Packaging
- Box
- VPE length
- 35 mm
- VPE width
- 105 mm
- VPE height
- 140 mm
Notes
- Notes
- Additional colours on request P on drawing = pitch Crimp form A for wire end ferrules with PZ 6/5 crimping tool are recommended for the largest cable sizes. Total load-carrying capacity of the potential bridges when feeding with 1.5 mm² is max. 17.5 A (so the capacity is 2.18 A for poles 2 through 9) Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 Conductor < 0.2 mm² tinned Max. outer diameter of the conductor: 2.9 mm Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
- IPC conformity
- Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.
Conductors Suitable For Connection
- Clamping range, min.
- 0.2 mm²
- Clamping range, max.
- 1.5 mm²
- Wire connection cross section AWG, min.
- AWG 24
- Wire connection cross section AWG, max.
- AWG 16
- Solid, min. H05(07) V-U
- 0.2 mm²
- Solid, max. H05(07) V-U
- 1.5 mm²
- Flexible, min. H05(07) V-K
- 0.2 mm²
- Flexible, max. H05(07) V-K
- 1.5 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, min.
- 0.2 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, max.
- 0.75 mm²
- W. wire end ferrule, DIN 46228 pt 1, min.
- 0.2 mm²
- W. wire end ferrule, DIN 46228 pt 1, max.
- 1 mm²
- Plug gauge in accordance with EN 60999 a x b; ø
- 2.4 mm x 1.5 mm; 1.9mm
- Reference text
- Other cables on request
- Max. clamping range
- 1.5 mm²
Rated Data Acc. To Csa
- Rated voltage (Use group B / CSA)
- 50 V
- Rated voltage (Use group D / CSA)
- 50 V
- Rated current (Use group B / CSA)
- 5 A
- Rated current (Use group D / CSA)
- 5 A
- Wire cross-section, AWG, min.
- AWG 22
- Wire cross-section, AWG, max.
- AWG 16
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro