Weidmuller

1782320000

ZDLD 2.5-2VN
1782320000
1782320000
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 42 Parts In-Stock da 11 Distributors

Additional Information

Part Number
1782320000

Approvals

Approvals
CE, CSA, EAC, RINA, UR
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Width
5.1 mm
Width (inches)
0.201 inch
Height
110.5 mm
Height (inches)
4.35 inch
Depth
69 mm
Depth (inches)
2.717 inch
Depth including DIN rail
70 mm
Net weight
18.91 g

Csa Rating Data

Certificate No. (CSA)
200039-1228250
Current size B (CSA)
15 A
Current size D (CSA)
10 A
Voltage size B (CSA)
300 V
Voltage size D (CSA)
300 V
Wire cross section max. (CSA)
12 AWG
Wire cross section min. (CSA)
26 AWG

Additional Technical Data

Explosion-tested version
No
Installation advice
Direct mounting
Number of similar terminals
1
Open sides
right
Type of mounting
Snap-on

Material Data

Material
Wemid
Colour
dark beige
UL 94 flammability rating
V-0

Safety Note

Safety notice
Safety Information

Classifications

ETIM 6.0
EC000897
ETIM 7.0
EC000897
EClass 9.0
27-14-11-20
EClass 9.1
27-14-11-20
EClass 10.0
27-14-11-20
UNSPSC
30-21-18-01

System Specifications

Version
Tension-clamp connection, Vertically cross-connected, for plug-in cross-connector, One end without connector
End cover plate required
Yes
Number of levels
3
Number of clamping points per level
2
Levels cross-connected internally
Yes
PE connection
No
Rail
TS 35

Temperatures

Storage temperature, max.
40 °C
Storage temperature, min.
10 °C
Storage temperature
10 °C...40 °C
Continuous operating temp., min.
-50 °C
Continuous operating temp., max.
120 °C

Rating Data

Rated cross-section
2.5 mm²
Rated voltage
400 V
Rated current
20 A
Current at maximum wires
20 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
1.33 mΩ
Power loss in accordance with IEC 60947-7-x
0.77 W
Rated impulse withstand voltage
6 kV
Pollution severity
3

Conductors For Clamping (Rated Connection)

Blade size
0.6 x 3.5 mm
Clamping range, max.
2.5 mm²
Clamping range, min.
0.08 mm²
Connection direction
top
Gauge to IEC 60947-1
A2
Number of connections
6
Stripping length
10 mm
Type of connection
Tension-clamp connection
Wire connection cross section AWG, max.
AWG 12
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
1.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded, min.
0.5 mm²
Wire connection cross-section, solid core, max.
2.5 mm²
Wire connection cross-section, solid core, min.
0.5 mm²

Ul Rating Data

Certificate No. (UR)
E60693
Conductor size Factory wiring max. (UR)
12 AWG
Conductor size Factory wiring min. (UR)
26 AWG
Conductor size Field wiring max. (UR)
12 AWG
Conductor size Field wiring min. (UR)
26 AWG
Current size B (UR)
15 A
Current size D (UR)
10 A
Voltage size B (UR)
300 V
Voltage size D (UR)
300 V