Weidmuller

1975350000

LL1N 5.00/12/90 3.2SN OR BX
1975350000
1975350000
1975350000
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.
Offerta con tempi di consegna del produttore
Spedizione in:1 - 2 Molti giorni lavorativi
Miglior prezzo:
€5.33

Additional Information

Part Number
1975350000

Rated Data Acc. To Ul 1059

Institute (UR)
UR
Certificate No. (UR)
E60693
Rated voltage (Use group B / UL 1059)
300 V
Rated voltage (Use group D / UL 1059)
300 V
Rated current (Use group B / UL 1059)
20 A
Rated current (Use group D / UL 1059)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 12
Reference to approval values
Specifications are maximum values, details - see approval certificate.

Approvals

Approvals
CSA, EAC, UR
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Width
60.64 mm
Width (inches)
2.387 inch
Height
34.3 mm
Height (inches)
1.35 inch
Height of lowest version
31.1 mm
Depth
10.84 mm
Depth (inches)
0.427 inch
Net weight
26.26 g

Rated Data Acc. To Iec

Tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. number of poles (Tu=20°C)
32.5 A
Rated current, max. number of poles (Tu=20°C)
26 A
Rated current, min. number of poles (Tu=40°C)
27.5 A
Rated current, max. number of poles (Tu=40°C)
22 A
Rated voltage for surge voltage class / pollution degree II/2
500 V
Rated voltage for surge voltage class / pollution degree III/2
320 V
Rated voltage for surge voltage class / pollution degree III/3
250 V
Rated impulse voltage for surge voltage class/ pollution degree II/2
4 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2
4 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3
4 kV
Short-time withstand current resistance
3 x 1s with 120 A

Material Data

Insulating material
Wemid (PA)
Colour
orange
Colour chart (similar)
RAL 2000
Insulating material group
I
Comparative Tracking Index (CTI)
≥ 600
Insulation strength
≥ 108 Ω
UL 94 flammability rating
V-0
Contact material
Copper alloy
Contact surface
tinned
Coating
4-6 μm SN
Tinning type
matt
Layer structure of solder connection
2-4 µm Ni / 4-6 µm Sn matt
Storage temperature, min.
-25 °C
Storage temperature, max.
55 °C
Max. relative humidity during storage
80 %
Operating temperature, min.
-50 °C
Operating temperature, max.
120 °C
Temperature range, installation, min.
-25 °C
Temperature range, installation, max.
120 °C

Classifications

ETIM 6.0
EC002643
ETIM 7.0
EC002643
EClass 9.0
27-44-04-01
EClass 9.1
27-44-04-01
EClass 10.0
27-44-04-01
UNSPSC
30-21-18-11

System Parameters

Product family
OMNIMATE Signal - series LL
Wire connection method
Clamping yoke connection
Property, clamping point
WireReady
Mounting onto the PCB
THT solder connection
Conductor outlet direction
90°
Pitch in mm (P)
5 mm
Pitch in inches (P)
0.197 inch
Number of poles
12
Fitted by customer
Yes
Number of rows
1
Max. adjacent poles per row
12
Solder pin length (l)
3.2 mm
Solder pin dimensions
0.75 x 0.9 mm
Solder eyelet hole diameter (D)
1.3 mm
Solder eyelet hole diameter tolerance (D)
+ 0,1 mm
Number of solder pins per pole
1
Screwdriver blade
0.6 x 3.5
Screwdriver blade standard
DIN 5264
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.6 Nm
Clamping screw
M 3
Stripping length
6 mm
L1 in mm
55 mm
L1 in inches
2.167 inch
Touch-safe protection acc. to DIN VDE 0470
IP 20
Touch-safe protection acc. to DIN VDE 57 106
Safe from finger touch
Insulation strength
≥ 108 Ω

Packing

Packaging
Box
VPE length
45 mm
VPE width
120 mm
VPE height
325 mm

Notes

Notes
Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.

Conductors Suitable For Connection

Clamping range, min.
0.08 mm²
Clamping range, max.
6 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Solid, min. H05(07) V-U
0.5 mm²
Solid, max. H05(07) V-U
6 mm²
Flexible, min. H05(07) V-K
0.5 mm²
Flexible, max. H05(07) V-K
4 mm²
W. plastic collar ferrule, DIN 46228 pt 4, min.
0.5 mm²
W. plastic collar ferrule, DIN 46228 pt 4, max.
2.5 mm²
W. wire end ferrule, DIN 46228 pt 1, min.
0.5 mm²
W. wire end ferrule, DIN 46228 pt 1, max.
2.5 mm²
Plug gauge in accordance with EN 60999 a x b; ø
2.8 mm x 2.4 mm; 3.0 mm
Max. clamping range
6 mm²

Rated Data Acc. To Csa

Institute (CSA)
CSA
Certificate No. (CSA)
200039-1202191
Rated voltage (Use group B / CSA)
300 V
Rated voltage (Use group D / CSA)
300 V
Rated current (Use group B / CSA)
20 A
Rated current (Use group D / CSA)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 12
Reference to approval values
Specifications are maximum values, details - see approval certificate.