CEO63
- Fabrycznie Nowy915 szt.
- Nowy89 szt.
Filtry
LV HRC fuse link, NH000, In: 80 A, gG, Un AC: 400 V, Combination indicator, insulated grip lugs
LV HRC fuse link, NH000, In: 80 A, gG, Un AC: 400 V, Combination indicator, insulated grip lugs
1PK=3 FUSE LINKS,LV HRC,SZ3,425A,500V SIZE 3, 425A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
1PK=3 FUSE LINKS,LV HRC,SZ3,425A,500V SIZE 3, 425A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,800A,SZ4,500V SIZE 4, 800A, AC 500/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,800A,SZ4,500V SIZE 4, 800A, AC 500/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Switch Fuses,Front Operated,4-pole,04 (Left Side),DIN,0,1,Handle and shaft included,Switched - With Solid Link
Switch Fuses,Front Operated,4-pole,04 (Left Side),DIN,0,1,Handle and shaft included,Switched - With Solid Link
The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
FUSE,LV HRC,SIZE 00, 63A, 500V SIZE 00, 63A, 500V W. NON-INSULATED GRIPPING LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,SIZE 00, 63A, 500V SIZE 00, 63A, 500V W. NON-INSULATED GRIPPING LUGS LV HRC FUSE LINK GL/GG
CYL FUSE,FRENCH,10X38,500V,8A SIZE 10X38MM, 500V 8A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
CYL FUSE,FRENCH,10X38,500V,8A SIZE 10X38MM, 500V 8A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
Switch Fuses,Front Operated,3-pole,03 (Left Side),DIN,000,00,Handle and shaft included,
Switch Fuses,Front Operated,3-pole,03 (Left Side),DIN,000,00,Handle and shaft included,
FUSE LINK,LV HRC,25A,500VAC,440VDC SIZE 0, 25A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,25A,500VAC,440VDC SIZE 0, 25A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG