Schneider Electric

ATV340U40N4E

1 / 1
thumbnail

Opis

Końcówka Serii
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 4kW / 5hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 2.2kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).
Country of Origin
ID
Part Number
ATV340U40N4E
Tariff Code
85044095
EAN
3606480967023
UNSPSC
39122001
Metody płatności:
Najlepsza oferta od:
SKZaufany dostawca Automa.Net
Dostępność:
10 szt.
W magazynie
Zaktualizowano: 07-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 89 części w magazynie od 15 dostawców
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (14)

ATV340U40N4E product image
Schneider Electric

ATV340U40N4E

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
8 szt.
W magazynie
Zaktualizowano: 06-11-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
ATV340U40N4E product image
Schneider Electric

ATV340U40N4E

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
8 szt.
W magazynie
Zaktualizowano: 06-11-2024
Oferta od:
FRZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
ATV340U40N4E product image
Schneider Electric

ATV340U40N4E

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
PLZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
ATV340U40N4E product image
Schneider Electric

ATV340U40N4E

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
7 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
TRZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€408.61

Specifications

Variant
standard version
Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP20
Phase
3 phase
Communication Port Protocol
EtherNet/IP || Modbus serial || Modbus TCP
Nominal Output Current
9.3 A
Product Specific Application
machine
Maximum Horse Power Rating
7 hp normal duty || 5 hp heavy duty
Supply Frequency
50...60 Hz +/- 5 %
Range Of Product
Altivar Machine ATV340
Motor Power Kw
5.5 kW normal duty || 4 kW heavy duty
[Us] Rated Supply Voltage
380...480 V - 15...10 %
Mounting Mode
cabinet mount
Emc Filter
class C3 EMC filter integrated

Complementary

Prospective Line Isc
5 kA
Power Dissipation In W
natural convection 99 W 380 V 4 kHz heavy duty) || forced convection 99 W 380 V 4 kHz heavy duty) || natural convection 130 W 380 V 4 kHz normal duty) || forced convection 130 W 380 V 4 kHz normal duty)
Line Current
11.4 A 380 V normal duty) || 9.0 A 480 V normal duty) || 13.4 A 380 V heavy duty) || 10.6 A 480 V heavy duty)
Line Current
13.4 A 380 V without line choke heavy duty) || 10.6 A 480 V without line choke heavy duty) || 11.4 A 380 V with external line choke normal duty) || 9 A 480 V with external line choke normal duty) || 8.5 A 380 V with external line choke heavy duty) || 6.8 A 480 V with external line choke heavy duty)
Analogue Output Type
software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Discrete Output Type
programmable output DQ1, DQ2 30 V DC 100 mA
Electrical Connection
screw terminal 1.5...4 mm² line side || screw terminal 4...6 mm² DC bus || screw terminal 1.5...4 mm² motor || screw terminal 0.2...2.5 mm² control
Asynchronous Motor Control Profile
constant torque standard || variable torque standard || optimized torque mode
Maximum Switching Current
relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
4 Quadrant Operation Possible
true
Apparent Power
9 kVA 480 V normal duty) || 8.8 kVA 480 V heavy duty)
Net Weight
2.3 kg
Type Of Polarization
no impedance
Relay Output Type
relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Switching Frequency
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current
14 A 60 s normal duty) || 14 A 60 s heavy duty) || 17.1 A 2 s normal duty) || 16.7 A 2 s heavy duty)
Analogue Input Number
2
Motor Slip Compensation
not available in permanent magnet motor law || adjustable || automatic whatever the load || can be suppressed
Discrete Output Number
2.0
Method Of Access
slave Modbus RTU || slave Modbus TCP
Number Of Addresses
1-247
Discrete Input Number
5
With Safety Function Safe Stop 1 (Ss1)
true
Width
85.0 mm
Transmission Rate
4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Depth
232.5 mm
Analogue Input Type
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
Electrical Connection
line side screw terminal 1.5...4 mm² AWG 14...AWG 12 || DC bus screw terminal 4...6 mm² AWG 12...AWG 10 || motor screw terminal 1.5...4 mm² AWG 14...AWG 12 || control screw terminal 0.2...2.5 mm² AWG 24...AWG 12
Maximum Output Frequency
0.599 kHz
With Safety Function Safe Brake Management (Sbc/Sbt)
true
Height
270.0 mm
Acceleration And Deceleration Ramps
linear adjustable separately from 0.01...9999 s || S, U or customized
Maximum Output Voltage
480 V
Base Load Current At High Overload
9.3 A
Transmission Frame
RTU
Relay Output Number
2
With Safety Function Safe Torque Off (Sto)
true
Data Format
8 bits, configurable odd, even or no parity
Base Load Current At Low Overload
12.7 A
Connector Type
3 RJ45
Pollution Degree
2 IEC 61800-5-1
Analogue Output Number
2
Physical Interface
2-wire RS 485
Minimum Switching Current
relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
Discrete Input Logic
16 preset speeds
Continuous Output Current
12.7 A 4 kHz normal duty || 9.3 A 4 kHz heavy duty
Brake Chopper Integrated
true
Output Voltage
<= power supply voltage
Nominal Switching Frequency
4 kHz
Braking To Standstill
by DC injection
Discrete Input Type
PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
Protection Type
thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive
With Safety Function Safely Limited Speed (Sls)
true
Synchronous Motor Control Profile
permanent magnet motor || reluctance motor

Offer Sustainability

Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Upgradeability
Upgraded components available
Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1609005EN
Sustainable Offer Status
Green Premium product
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI1609005EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || TÜV || EAC || CTick
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...9 Hz
Standards
IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C
Regulation Loop
adjustable PID regulator
Permitted Relative Humidity (During Operation)
class 3K5 according to EN 60721-3
Operating Altitude
<= 9842.52 ft (3000 m) with current derating above 1000m
Overvoltage Category
class III
Environmental Class (During Operation)
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Maximum Acceleration Under Shock Impact (During Operation)
70 m/s² at 22 ms
Pollution Degree
2
Electromagnetic Compatibility
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Ambient Air Temperature For Operation
-15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
Volume Of Cooling Air
19.0 m3/h
Marking
CE
Maximum Acceleration Under Vibrational Stress (During Operation)
5 m/s² at 9...200 Hz
Noise Level
49.5 dB
Ambient Air Temperature For Storage
-40-70 °C
Type Of Cooling
forced convection
Isolation
between power and control terminals
Assembly Style
with heat sink
Operating Position
vertical +/- 10 degree
Ambient Air Transport Temperature
-40-70 °C

Modele CAD

traceparts
traceparts
Pobierz