- Prospective Line Isc
- 5 kA
- Power Dissipation In W
- natural convection 99 W 380 V 4 kHz heavy duty) || forced convection 99 W 380 V 4 kHz heavy duty) || natural convection 130 W 380 V 4 kHz normal duty) || forced convection 130 W 380 V 4 kHz normal duty)
- Line Current
- 11.4 A 380 V normal duty) || 9.0 A 480 V normal duty) || 13.4 A 380 V heavy duty) || 10.6 A 480 V heavy duty)
- Line Current
- 13.4 A 380 V without line choke heavy duty) || 10.6 A 480 V without line choke heavy duty) || 11.4 A 380 V with external line choke normal duty) || 9 A 480 V with external line choke normal duty) || 8.5 A 380 V with external line choke heavy duty) || 6.8 A 480 V with external line choke heavy duty)
- Analogue Output Type
- software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
- Discrete Output Type
- programmable output DQ1, DQ2 30 V DC 100 mA
- Electrical Connection
- screw terminal 1.5...4 mm² line side || screw terminal 4...6 mm² DC bus || screw terminal 1.5...4 mm² motor || screw terminal 0.2...2.5 mm² control
- Asynchronous Motor Control Profile
- constant torque standard || variable torque standard || optimized torque mode
- Maximum Switching Current
- relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
- 4 Quadrant Operation Possible
- true
- Apparent Power
- 9 kVA 480 V normal duty) || 8.8 kVA 480 V heavy duty)
- Net Weight
- 2.3 kg
- Type Of Polarization
- no impedance
- Relay Output Type
- relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
- Switching Frequency
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Maximum Transient Current
- 14 A 60 s normal duty) || 14 A 60 s heavy duty) || 17.1 A 2 s normal duty) || 16.7 A 2 s heavy duty)
- Analogue Input Number
- 2
- Motor Slip Compensation
- not available in permanent magnet motor law || adjustable || automatic whatever the load || can be suppressed
- Discrete Output Number
- 2.0
- Method Of Access
- slave Modbus RTU || slave Modbus TCP
- Number Of Addresses
- 1-247
- Discrete Input Number
- 5
- With Safety Function Safe Stop 1 (Ss1)
- true
- Width
- 85.0 mm
- Transmission Rate
- 4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- Depth
- 232.5 mm
- Analogue Input Type
- AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
- Electrical Connection
- line side screw terminal 1.5...4 mm² AWG 14...AWG 12 || DC bus screw terminal 4...6 mm² AWG 12...AWG 10 || motor screw terminal 1.5...4 mm² AWG 14...AWG 12 || control screw terminal 0.2...2.5 mm² AWG 24...AWG 12
- Maximum Output Frequency
- 0.599 kHz
- With Safety Function Safe Brake Management (Sbc/Sbt)
- true
- Height
- 270.0 mm
- Acceleration And Deceleration Ramps
- linear adjustable separately from 0.01...9999 s || S, U or customized
- Maximum Output Voltage
- 480 V
- Base Load Current At High Overload
- 9.3 A
- Transmission Frame
- RTU
- Relay Output Number
- 2
- With Safety Function Safe Torque Off (Sto)
- true
- Data Format
- 8 bits, configurable odd, even or no parity
- Base Load Current At Low Overload
- 12.7 A
- Connector Type
- 3 RJ45
- Pollution Degree
- 2 IEC 61800-5-1
- Analogue Output Number
- 2
- Physical Interface
- 2-wire RS 485
- Minimum Switching Current
- relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
- Discrete Input Logic
- 16 preset speeds
- Continuous Output Current
- 12.7 A 4 kHz normal duty || 9.3 A 4 kHz heavy duty
- Brake Chopper Integrated
- true
- Output Voltage
- <= power supply voltage
- Nominal Switching Frequency
- 4 kHz
- Braking To Standstill
- by DC injection
- Discrete Input Type
- PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
- Protection Type
- thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive
- With Safety Function Safely Limited Speed (Sls)
- true
- Synchronous Motor Control Profile
- permanent magnet motor || reluctance motor