1 / 1
thumbnail

Opis

Końcówka Serii
This Compact NSX250F is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 200A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX250F is part of Schneider Electric EcoStruxure Power architecture.
Country of Origin
PL
Part Number
LV431651
Tariff Code
85362090
EAN
3606480014383
UNSPSC
39121633
Metody płatności:
Najlepsza oferta od:
DEZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 31-10-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Specifications

Network Frequency
50/60 Hz
Line Rated Current
200 A 40 °C
Trip Unit Name
TM-D
Range Of Product
ComPact NSX100...250
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz
Trip Unit Protection Functions
LI
Network Type
AC
Protected Poles Description
4t
Product Or Component Type
circuit breaker
Product Name
ComPact NSX
Range
ComPact
Control Type
toggle
Utilisation Category
category A
Mounting Mode
fixed
Breaking Capacity
85 kA 240 V AC 50/60 Hz UL 508 || 22 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 35 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 36 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 || 85 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 480 V AC 50/60 Hz UL 508 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 15 kA 600 V AC 50/60 Hz UL 508
Suitability For Isolation
yes EN/IEC 60947-2
Poles Description
4P
Breaking Capacity Code
F 36 kA 415 V AC
Neutral Position
left
Device Application
distribution
Device Short Name
NSX250F
Trip Unit Technology
thermal-magnetic

Contractual warranty

Warranty
18 months

Complementary

[Ics] Rated Service Breaking Capacity
35 kA 440 V AC 50/60 Hz IEC 60947-2 || 36 kA 380/415 V AC 50/60 Hz IEC 60947-2 || 85 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 22 kA 525 V AC 50/60 Hz IEC 60947-2 || 30 kA 500 V AC 50/60 Hz IEC 60947-2 || 8 kA 660/690 V AC 50/60 Hz IEC 60947-2
Height
161 mm
Earth-Leakage Protection
without
Mounting Support
backplate
Downside Connection
front
Number Of Slots
5
Protection Type
L : for overload protection (thermal) || I : for short-circuit protection (magnetic)
Long Time Delay Adjustment Type
fixed
Net Weight
2.8 kg
[Tr] Long-Time Delay Adjustment Range
120-400 s 1.5 x In || 15-15 s 6 x Ir
Electrical Durability
5000 cycles 690 V In || 10000 cycles 690 V In/2 || 10000 cycles 440 V In || 20000 cycles 440 V In/2
Short-Time Delay Adjustment Type
fixed
Neutral Protection Setting
1 x Ir 4t)
Long Time Pick-Up Adjustment Type Ir
adjustable
Long Time Pick-Up Adjustment Range
0.7...1 x In
Upside Connection
front
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz
Trip Unit Rating
200-200 A 40 °C
Mechanical Durability
20000 cycles
[Isd] Short-Time Pick-Up Adjustment Range
5...10 x In
Connection Pitch
35 mm
[Uimp] Rated Impulse Withstand Voltage
8 kV
Width
140 mm
Depth
86 mm
Short-Time Pick-Up Adjustment Type Isd
adjustable

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP120606EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI120604EN
Eu Rohs Directive
Compliant

Environment

Product Certifications
CCC || Marine || EAC
Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60947
Ip Degree Of Protection
IP40 conforming to IEC 60529
Electrical Shock Protection Class
class II
Pollution Degree
3 IEC 60664-1
Ambient Air Temperature For Storage
-50-85 °C
Relative Humidity
0-95 %
Operating Altitude
0...6561.68 ft (0...2000 m) without derating || 2000 m...5000 m with derating
Overvoltage Category
class II

Modele CAD

traceparts
traceparts
Pobierz