Fluke
Fluke 1587/ET Kit
1 / 1
- Part Number
- Fluke 1587/ET Kit
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Mechanical and General Specifications
- Warranty
- 1 year
- Size
- 203 x 100 x 50 mm (with holster)
- Maximum conductor diameter
- 32 mm (1.25 in)
- Weight
- 624 g
- Warranty
- 3 years
- Maximum conductor size (busbar)
- 750 MCM
- Battery life Alkaline Meter use
- 1000 hours
- Output cable length
- 1.5 m (59 in)
- Shrouded banana plugs
- Yes
- Battery life Alkaline Insulation test use
- Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
- IP Rating
- IP40
Insulation Test
- Minimum test current @ 1 kΩ/V
- 1 mA
- Test voltages
- 50, 100, 250, 500, 1000 V
- Maximum resistance per test voltage
- 50 V || 100 V || 250 V || 500 V || 1000 V: 2 GΩ
- Maximum resolution per test voltage
- 50 V: 0.01 MΩ || 100 V: 0.01 MΩ || 250 V: 0.1 MΩ || 500 V: 0.1 MΩ || 1000 V: 0.1 MΩ
- Accuracy per test voltage
- 50 V: ±(3% + 5) || 100 V: ±(3% + 5) || 250 V: ±(1.5% + 5) || 500 V: ±(1.5% + 5) || 1000 V: ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Specifications
- Temperature range
- -30°C to 650°C (-22°F to 1202°F)
- Voltage DC Maximum voltage
- 1000 V
- Nominal current range
- 400 A
- Accuracy
- ±1.0°C or ±1.0% of reading, whichever is greater-10°C to 0°C: ±2.0-30°C to -10°C: ±3.0
- Voltage DC Accuracy
- ±(0.09% + 2)
- Continuous current range
- 1 A - 400 A
- Maximum non-destructive current
- 1000 A
- Voltage DC Maximum resolution
- 0.001V
- Response time (95%) Fluke 62 MAX+
- < 300 ms (95% of reading)
- Response time (95%) Spectral response
- 8 to 14 microns
- Lowest measurable current
- 1 A
- Voltage AC Maximum voltage
- 1000 V
- Response time (95%) Emissivity
- 0.10 to 1.00
- Basic accuracy
- 2% + 0.06 A(45 - 400 Hz)(% reading + floorspec)
- Voltage AC Accuracy
- ±(2% + 3)
- Voltage AC AC bandwidth
- 5 kHz1 || 1. With low pass filter; 3 db @ 800 Hz
- Optical resolution
- 12:1 (calculated at 90% energy)
- Useable frequency
- 5 Hz - 20 kHz
- Voltage AC Maximum resolution
- 0.1 mV
- Output level(s)
- 1 mA/A
- Display resolution
- 0.1°C (0.2°F)
- Repeatability of readings
- ±0.5% of reading or < ±0.5°C (1°F), whichever is greater
- Current DC Maximum amps
- 400 mA
- Power
- AA battery
- Current DC Amps accuracy
- ±(0.2% + 2)
- Current DC Maximum Resolution
- 0.01 mA
- Battery life
- 8 hours with laser and backlight on
- Physical specifications Weight
- 255 g (8.99 oz)
- Current AC Maximum amps
- 400 mA
- Current AC Amps accuracy
- ±(1.5% + 2) 1 || 1. 1 kHz bandwidth
- Physical specifications Size
- 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
- Current AC Maximum resolution
- 0.01 mA
- Physical specifications
- Operating temperature: 0°C to 50°C (32°F to 122°F) || Operating humidity: 10% to 90% RH non-condensing at 30°C (86°F) || Operating altitude: 2000 meters above mean sea level || IP rating: IP 54 per IEC 60529 || Vibration and shock: IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
- Physical specifications Storage temperature
- -20°C to 60°C (-4°F to 140°F), (without battery)
- Resistance Maximum resistance
- 50 MΩ
- Resistance Accuracy
- ±(0.9% + 2)
- Physical specifications Storage altitude
- 12,000 meters above mean sea level
- Resistance Maximum resolution
- 0.1 Ω
- Physical specifications Drop test
- 3 meters
- Physical specifications EMC
- EN 61326-1:2006 EN 61326-2:2006
- Capacitance Maximum capacitance
- 9,999 µF
- Capacitance Accuracy
- ±(1.2% + 2)
- Standards and agency approval Compliance
- EN/IEC 61010-1: 2001
- Standards and agency approval Laser safety
- FDA and EN 60825-1 Class II
- Capacitance Maximum resolution
- 1 nF
- Frequency Maximum frequency
- 100 kHz
- Frequency Accuracy
- ±(0.1% + 1)
- Frequency Maximum resolution
- 0.01 Hz
- Temperature measurement
- -40.0°C to 537°C-40.0°F to 998°Fexcluding probe
- Diode test Range
- 6 V
- Diode test Resolution
- 1 mV
- Diode test Accuracy
- ±(2% + 1)
Safety Specifications
- Overvoltage category
- Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
- Safety
- CAT IV 600 V, CAT III, 1000 V
- Maximum voltage
- 1000 V AC rms from earth to ground, in compliance with EN61010
- Agency approvals
- 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Environmental Specifications
- Operating temperature
- –20°C to +55°C
- Storage temperature
- -40°C to +60°C
- Humidity (without condensation)
- 0% - 95% (10°C – 30°C) || 0% - 75% (30°C – 40°C) || 0% - 40% (40°C – 55°C)
- Operating altitude
- 2000 m
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro