Mechanical and General Specifications

Warranty
1 year
Size
203 x 100 x 50 mm (with holster)
Maximum conductor diameter
32 mm (1.25 in)
Weight
624 g
Warranty
3 years
Maximum conductor size (busbar)
750 MCM
Battery life Alkaline Meter use
1000 hours
Output cable length
1.5 m (59 in)
Shrouded banana plugs
Yes
Battery life Alkaline Insulation test use
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
IP40

Insulation Test

Minimum test current @ 1 kΩ/V
1 mA
Test voltages
50, 100, 250, 500, 1000 V
Maximum resistance per test voltage
50 V || 100 V || 250 V || 500 V || 1000 V: 2 GΩ
Maximum resolution per test voltage
50 V: 0.01 MΩ || 100 V: 0.01 MΩ || 250 V: 0.1 MΩ || 500 V: 0.1 MΩ || 1000 V: 0.1 MΩ
Accuracy per test voltage
50 V: ±(3% + 5) || 100 V: ±(3% + 5) || 250 V: ±(1.5% + 5) || 500 V: ±(1.5% + 5) || 1000 V: ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ

Specifications

Temperature range
-30°C to 650°C (-22°F to 1202°F)
Voltage DC Maximum voltage
1000 V
Nominal current range
400 A
Accuracy
±1.0°C or ±1.0% of reading, whichever is greater-10°C to 0°C: ±2.0-30°C to -10°C: ±3.0
Voltage DC Accuracy
±(0.09% + 2)
Continuous current range
1 A - 400 A
Maximum non-destructive current
1000 A
Voltage DC Maximum resolution
0.001V
Response time (95%) Fluke 62 MAX+
< 300 ms (95% of reading)
Response time (95%) Spectral response
8 to 14 microns
Lowest measurable current
1 A
Voltage AC Maximum voltage
1000 V
Response time (95%) Emissivity
0.10 to 1.00
Basic accuracy
2% + 0.06 A(45 - 400 Hz)(% reading + floorspec)
Voltage AC Accuracy
±(2% + 3)
Voltage AC AC bandwidth
5 kHz1 || 1. With low pass filter; 3 db @ 800 Hz
Optical resolution
12:1 (calculated at 90% energy)
Useable frequency
5 Hz - 20 kHz
Voltage AC Maximum resolution
0.1 mV
Output level(s)
1 mA/A
Display resolution
0.1°C (0.2°F)
Repeatability of readings
±0.5% of reading or < ±0.5°C (1°F), whichever is greater
Current DC Maximum amps
400 mA
Power
AA battery
Current DC Amps accuracy
±(0.2% + 2)
Current DC Maximum Resolution
0.01 mA
Battery life
8 hours with laser and backlight on
Physical specifications Weight
255 g (8.99 oz)
Current AC Maximum amps
400 mA
Current AC Amps accuracy
±(1.5% + 2) 1 || 1. 1 kHz bandwidth
Physical specifications Size
175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Current AC Maximum resolution
0.01 mA
Physical specifications
Operating temperature: 0°C to 50°C (32°F to 122°F) || Operating humidity: 10% to 90% RH non-condensing at 30°C (86°F) || Operating altitude: 2000 meters above mean sea level || IP rating: IP 54 per IEC 60529 || Vibration and shock: IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
Physical specifications Storage temperature
-20°C to 60°C (-4°F to 140°F), (without battery)
Resistance Maximum resistance
50 MΩ
Resistance Accuracy
±(0.9% + 2)
Physical specifications Storage altitude
12,000 meters above mean sea level
Resistance Maximum resolution
0.1 Ω
Physical specifications Drop test
3 meters
Physical specifications EMC
EN 61326-1:2006 EN 61326-2:2006
Capacitance Maximum capacitance
9,999 µF
Capacitance Accuracy
±(1.2% + 2)
Standards and agency approval Compliance
EN/IEC 61010-1: 2001
Standards and agency approval Laser safety
FDA and EN 60825-1 Class II
Capacitance Maximum resolution
1 nF
Frequency Maximum frequency
100 kHz
Frequency Accuracy
±(0.1% + 1)
Frequency Maximum resolution
0.01 Hz
Temperature measurement
-40.0°C to 537°C-40.0°F to 998°Fexcluding probe
Diode test Range
6 V
Diode test Resolution
1 mV
Diode test Accuracy
±(2% + 1)

Safety Specifications

Overvoltage category
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Safety
CAT IV 600 V, CAT III, 1000 V
Maximum voltage
1000 V AC rms from earth to ground, in compliance with EN61010
Agency approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V

Environmental Specifications

Operating temperature
–20°C to +55°C
Storage temperature
-40°C to +60°C
Humidity (without condensation)
0% - 95% (10°C – 30°C) || 0% - 75% (30°C – 40°C) || 0% - 40% (40°C – 55°C)
Operating altitude
2000 m