1 / 1
thumbnail

Descripción

Activo maduro
Altivar Machine ATV12 is an offer of variable speed drives for commercial equipment and simple machines. The drive can feed three-phase asynchronous motors. It works at a rated power up to 1.5kW, and a rated voltage from 200V to 240V. It has advanced PID and catch on the fly functions, basic cabling, and easy motor control setting. Based on the needs, it can be delivered without heatsink, with embedded EMC filter, or as standard version. The Altivar 12 drive integrates as standard the Modbus communication protocol. It weighs 1kg. This Altivar Machine ATV12 is designed for simple applications, in industry, commercial machines and HVAC machines such as conveyors, pumps, extractors, access barriers and treadmills. It conforms to IEC, UL and other international standards. SoMove software compatibility enables saving and transfering of configurations to spare drive, thus reducing maintenance downtime. This reference is sold individually. ATV12 can be installed alone or side by side in a multi-drive configuration. The ATV12 range meets basic machine requirements united with simplicity.
Country of Origin
ID
Part Number
ATV12PU15M3
Tariff Code
85044095
EAN
3606480071232
UNSPSC
39122001
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 04-11-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Environment

Product Certifications
NOM || CSA || C-tick || UL || GOST || RCM || KC
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
Standards
UL 508C || UL 618000-5-1 || IEC 61800-5-1 || IEC 61800-3
Vibration Resistance
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - IEC 60068-2-6
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Regulation Loop
adjustable PID regulator
Operating Altitude
<= 3280.84 ft (1000 m) without derating || > 3280.84...9842.52 ft (> 1000...3000 m) with current derating 1 % per 100 m
Overvoltage Category
class III
Environmental Class (During Operation)
class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
Electromagnetic Emission
radiated emissions environment 1 category C2 IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions with additional EMC filter environment 1 category C1 IEC 61800-3 4...12 kHz shielded motor cable <5 m || conducted emissions with additional EMC filter environment 1 category C2 IEC 61800-3 4...12 kHz shielded motor cable <20 m || conducted emissions with additional EMC filter environment 2 category C3 IEC 61800-3 4...12 kHz shielded motor cable <20 m
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
Pollution Degree
2
Electromagnetic Compatibility
electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || electrostatic discharge immunity test level 3 IEC 61000-4-2 || immunity to conducted disturbances level 3 IEC 61000-4-6 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || surge immunity test level 3 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11
Ambient Air Temperature For Operation
-10-40 °C without derating || 40-60 °C with current derating 2.2 % per °C
Marking
CE
Maximum Acceleration Under Vibrational Stress (During Operation)
10 m/s² at 13...200 Hz
Noise Level
0 dB
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Style
on base plate
Operating Position
vertical +/- 10 degree
Ambient Air Transport Temperature
-25-70 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Rohs Exemption Information
Yes
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Prospective Line Isc
5 kA
Network Frequency
50-60 Hz
Power Dissipation In W
natural 73.0 W
Line Current
11.1 A 100 V heavy duty) || 9.3 A 120 V heavy duty)
Asynchronous Motor Control Profile
voltage/frequency ratio (V/f) || sensorless flux vector control || quadratic voltage/frequency ratio
Relative Symmetric Network Frequency Tolerance
5 %
Apparent Power
3.9 kVA 240 V heavy duty)
Net Weight
1 kg
Type Of Polarization
no impedance
Frequency Resolution
analog input converter A/D, 10 bits || display unit 0.1 Hz
Switching Frequency
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current
11.2 A 60 s heavy duty) || 12.4 A 2 s heavy duty)
Communication Service
read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
Analogue Input Number
1
Motor Slip Compensation
adjustable || preset in factory
Discrete Output Number
2
Method Of Access
server Modbus serial
Number Of Addresses
1-247
Speed Range
1-20
Discrete Input Number
4
Linearity Error
+/- 0.3 % of maximum value analogue input
Width
105 mm
Transmission Rate
9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Depth
98.2 mm
Sampling Duration
20 ms +/- 1 ms logic input || 10 ms analogue input
Maximum Output Frequency
4 kHz
Height
143 mm
Acceleration And Deceleration Ramps
U || S || linear from 0 to 999.9 s
Time Constant
20 ms +/- 1 ms for reference change
Maximum Output Voltage
240 V
Base Load Current At High Overload
7.5 A
Speed Drive Output Frequency
0.5-400 Hz
Transmission Frame
RTU
Relay Output Number
1
Transient Overtorque
150-170 % of nominal motor torque depending on drive rating and type of motor
Data Format
8 bits, configurable odd, even or no parity
Connector Type
1 RJ45
Analogue Output Number
1
Physical Interface
2-wire RS 485
Insulation
electrical between power and control
Tightening Torque
1.2 N.m
Continuous Output Current
7.5 A 4 kHz
Nominal Switching Frequency
4 kHz
Quantity Per Set
set of 1
Braking To Standstill
by DC injection
Protection Type
line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by continuous calculation of I²t

Specifications

Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP20
Communication Port Protocol
Modbus
Nominal Output Current
7.5 A
Product Specific Application
simple machine
Maximum Horse Power Rating
2 hp
Supply Frequency
50/60 Hz +/- 5 %
Range Of Product
Altivar 12
Motor Power Kw
1.5 kW
[Us] Rated Supply Voltage
200...240 V - 15...10 %
Mounting Mode
cabinet mount
Emc Filter
without EMC filter

Modelos CAD

traceparts
traceparts
Descargar