1 / 8
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Descrizione

Attivo maturo
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on both the line and load sides. This PowerPacT Q, 100A, 3 pole, circuit breaker has an interrupting rating of 25kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
Country of Origin
MX
Part Number
QDL32100
Tariff Code
8536200020
EAN
39121616
UPC
785901662402
UNSPSC
39121616
Metodi di pagamento:
Migliore offerta da:
USFornitore Automa.Net di fiducia
Disponibilità:
16 pz.
Disponibile
Aggiornato il: 09-11-2024
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Environment

Ambient Air Temperature For Operation
40-70 °C
Standards
UL || CSA || NEMA || NOM-003-SCFI-2000
Product Certifications
UL || CSA || NOM

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1406032EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Complementary

Mounting Mode
unit mount lug)
Network Frequency
50/60 Hz
Trip Unit Technology
thermal-magnetic
Height
6.47 in
[Ue] Rated Operational Voltage
240 V AC 50/60 Hz UL
Tightening Torque
28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
Mounting Support
lug
Breaking Capacity Code
D
Magnetic Tripping Current
2400-2400 A
Local Signalling
1 trip indicator green)
Electrical Connection
lugs, load || lugs, line
[Uimp] Rated Impulse Withstand Voltage
8 kV UL
Magnetic Hold Current
1200 A
Control Type
operating handle
Circuit Breaker Application
HACR rated
Wire Stripping Length
22 mm
Utilisation Category
category A
Line Rated Current
100-100 A
Continuous Current Rating
80 %
Breaking Capacity
25 kA 120/208 V AC 50/60 Hz UL || 25 kA 240 V AC 50/60 Hz UL
Mechanical Durability
1000 cycles loaded || 5000 cycles no load
Poles Description
3P
Line Rated Current
100 A
Width
4.5 in
Depth
3.93 in

Specifications

Product Or Component Type
circuit breaker
Product Name
PowerPact Q
Range
PowerPact
Device Application
distribution

Documenti

Data Sheet

Scaricare