1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Descrizione

Attivo maturo
This Harmony RM35-U multi function control relay allows monitoring of voltage control. This modular multi function control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
Country of Origin
ID
Part Number
RM35UA12MW
Tariff Code
85364900
EAN
3389119405300
UNSPSC
39122331
£87.65
net
1
Metodi di pagamento:
Migliore offerta da:
GBFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 30-09-2024
Consegna stimata:
Su richiesta
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Un totale di 66 Parts In-Stock da 18 Distributors
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Offerte Disponibili (21)

RM35UA12MW product image
Schneider Electric

RM35UA12MW

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
ITFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€116.85
net
RM35UA12MW product image
Schneider Electric

RM35UA12MW

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
3 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
GBFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
£151.76
net
RM35UA12MW product image
Schneider Electric

RM35UA12MW

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
DEFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€155.83
net
RM35UA12MW product image
Schneider Electric

RM35UA12MW

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
2 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
NLFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€171.16
net
RM35UA12MW product image
Schneider Electric

RM35UA12MW

Condizione:
Nuovo sigillato in fabbrica
Disponibile:
3 pz.
Disponibile
Aggiornato il: 09-11-2024
Offerta da:
ESFornitore Automa.Net di fiducia
Consegna stimata:
Su richiesta
1
€179.74
net
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€44.12

Environment

Product Certifications
GOST || C-tick || UL || GL || CSA
Standards
IEC 60255-6
Non-Dissipating Shock Wave
4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
Dielectric Test Voltage
2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
Electromagnetic Compatibility
emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Shock Resistance
5 gn IEC 60068-2-27
Ambient Air Temperature For Operation
-20-50 °C
Vibration Resistance
0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
Ip Degree Of Protection
IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Pollution Degree
3 IEC 60664-1
Directives
73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
95-95 % 55-55 °C IEC 60068-2-30

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1504008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1504008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

[Us] Rated Supply Voltage
24...240 V AC/DC 50/60 Hz +/- 10 %
Safety Reliability Data
B10d = 290000 || MTTFd = 308.2 years
Maximum Measuring Cycle
30 ms measurement cycle as true rms value
Control Circuit Voltage Limits
15 % + 10 % Un
Hysteresis
5-50 % threshold setting
Insulation Resistance
> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
Measurement Error
+/- 0.05 %/°C with temperature variation || < 1 % over the whole range with voltage variation
Operating Rate
<= 360 operations/hour full load
Output Contacts
2 C/O
Immunity To Microbreaks
10 ms
Polarity
non reversible polarity on DC supply
Operating Position
any position without derating
Sensitivity Scale
1...10 V E1-M terminals || 10...100 V E3-M terminals || 5...50 V E2-M terminals
Net Weight
0.08 kg
Threshold Setting
10...100 %
Maximum Switching Voltage
250 V AC/DC
Reset Time
1500 ms time delay
Run-Up Delay At Power-Up
600 ms
Connections - Terminals
screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Ui] Rated Insulation Voltage
250 V IEC 60664-1 || 600 V IEC 60664-1
Overvoltage Category
III IEC 60664-1
Quality Labels
CE
Supply Voltage Limits
20.4-264 V AC/DC
Mounting Support
35 mm symmetrical DIN rail conforming to IEC 60715
Nominal Output Current
5 A
Local Signalling
for power ON LED (green) || for relay ON LED (yellow)
Mechanical Durability
30000000 cycles
Compatibility Code
RM3
Housing Material
self-extinguishing plastic
Resistance Across Terminals
110 mOhm E2-M terminals || 22 mOhm E1-M terminals || 220 mOhm E3-M terminals
Control Circuit Frequency
40...70 Hz +/- 10 %
Measurement Accuracy
+/- 10 % of the full scale value
Width
35 mm
Tightening Torque
0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W
0.6 W DC
Electrical Durability
100000 cycles
Repeat Accuracy
+/- 0.5 % input and measurement circuit || +/- 2 % time delay

Specifications

Minimum Switching Current
10 mA 5 V DC
Maximum Switching Current
5 A AC/DC
Range Of Product
Harmony Control Relays
Measurement Range
1...100 V voltage
Power Consumption In Va
0-3.5 VA AC
Switching Capacity In Va
1250 VA
Product Or Component Type
voltage control relay
Utilisation Category
AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
Relay Name
RM35UA
Contacts Type And Composition
2 C/O
Relay Type
multifunction voltage control relay
Time Delay Type
adjustable 0.3...30 s, 0 + 10 % on crossing the threshold
Relay Monitored Parameters
overvoltage or undervoltage detection

Modelli CAD

traceparts
traceparts
Scaricare