- Data Backed Up
- 128 MB built-in flash memory backup of user programs
- Electrical Connection
- removable screw terminal block power supply pitch 5.08 mm)
- Height
- 90 mm
- Canopen Feature Profile
- DR 303-1 || DS 301 V4.02
- Inrush Current
- 50 A
- Power Consumption In W
- 32.6-40.4 W with max number of I/O expansion module)
- Port Ethernet
- Ethernet 10BASE-T/100BASE-TX - 2 copper cable
- Transmission Rate
- 1.2...115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2...115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s 3-3 m USB
- Clock Drift
- <= 60 s/month 25-25 °C
- Battery Type
- BR2032 lithium non-rechargeable 4 year(s)
- Communication Port Protocol
- USB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
- Marking
- CE
- Backup Time
- 2 years 25 °C
- Maximum Number Of I/O Expansion Module
- 7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
- Net Weight
- 0.22 kg
- Application Structure
- 3 cyclic master tasks + 1 freewheeling task || 8 event tasks || 4 cyclic master tasks || 8 external event tasks
- Memory Capacity
- 64 MB system memory RAM
- Supply Voltage Limits
- 20.4-28.8 V
- Integrated Connection Type
- USB port mini B USB 2.0 || non isolated serial link serial RJ45 RS232/RS485 || dual-port Ethernet RJ45 || CANopen J1939 SUB-D 9
- Mounting Support
- top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
- Communication Service
- DHCP client || downloading || Ethernet/IP slave device || IEC VAR ACCESS || Modbus TCP client || Modbus TCP server || Modbus TCP slave device || monitoring || NGVL || programming || updating firmware || SMS notifications || FTP client/server || SNMP client/server || SQL client || send and receive email from the controller based on TCP/UDP library || web server (WebVisu & XWeb system) || OPC UA server || DNS client
- Local Signalling
- for PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for I/O error (I/O) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for Ethernet port activity 1 LED (green) || for SL 1 LED (green) || for bus fault on TM4 (TM4) 1 LED (red) || for CANopen run 1 LED (green) || for CANopen error 1 LED (green)
- Surge Withstand
- 1 kV shielded cable common mode IEC 61000-4-5 || 1 kV power lines common mode IEC 61000-4-5 || 0.5 kV power lines differential mode IEC 61000-4-5
- Execution Time For 1 Kinstruction
- 0.3 ms event and periodic task || 0.7 ms other instruction
- Realtime Clock
- with
- Web Services
- web server
- Width
- 54 mm
- Maximum Number Of Connections
- 8 Modbus server || 8 Modbus client || 16 Ethernet/IP target || 4 FTP server || 10 web server || 8 SoMachine protocol
- Number Of Slave
- 63 CANopen
- Depth
- 95 mm
- Data Storage Equipment
- <= 16 GB SD card optional)
- Insulation
- non-insulated between supply and internal logic || between supply and ground 500 V AC
- Supply
- serial)serial link supply 5 V, <200 mA