- Product Certifications
- CE || UL Listed
- [Us] Rated Supply Voltage
- 110...230 V AC/DC
- Setting Accuracy Of Time Delay
- +/- 10 % of full scale 25 °C IEC 61812-1
- Ambient Air Temperature For Operation
- -20-60 °C
- Height
- 62 mm
- Resistance To Electromagnetic Fields
- 10 V/m 80 MHz...1 GHz level 3 IEC 61000-4-3 || 3 V/m 1.4...2 GHz level 2 IEC 61000-4-3 || 1 V/m 2...2.7 GHz level 1 IEC 61000-4-3
- Diameter
- 29 mm
- Maximum Voltage Drop
- 5 V
- Standards
- IEC 61812-1 || UL 508
- Disturbance Radiated/Conducted
- class B EN 50022
- Repeat Accuracy
- +/- 0.5 %
- Mounting Diameter
- 22 mm
- Power Consumption In W
- 1 W
- Shape Of Signaling Unit Head
- round
- Dielectric Strength
- 1500 V IEC 61812-1
- Vibration Resistance
- 0.15 mm 10-60 Hz)IEC 60068-2-6 || 2 gn 60-150 Hz)IEC 60068-2-6
- Shock Resistance
- +/- 15 gn 11 ms 6 shocks on each axis)IEC 60068-2-27
- Reset Time
- 30 ms after time delay on de-energisation || 60 ms during time delay on de-energisation
- Net Weight
- 0.027 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV IEC 60947-1 || 4 kV IEC 60664-1
- Fixing Collar Material
- plastic
- Voltage Drift
- +/- 0.2 %/V
- Device Presentation
- monolithic product
- Thickness
- 1-6 mm
- Electromagnetic Compatibility
- electrostatic discharge 6 kV level 3 conforming to IEC 61000-4-2 || electromagnetic emission class B conforming to IEC 55011
- Temperature Drift
- +/- 0.05 %/°C
- Time Delay Range
- 3...60 s
- Local Signalling
- LED green, steady timing in progress || LED, off no timing in progress and output relay energised
- Pollution Degree
- 3 IEC 60664-1
- [Ui] Rated Insulation Voltage
- 250 V IEC 60947-1 || 250 V IEC 60664-1
- Ambient Air Temperature For Storage
- -20-80 °C
- Surge Withstand
- 2 kV, level 3 IEC 61000-4-5
- Power Consumption In Va
- 1.5 VA
- Overvoltage Category
- class 3 IEC 60536 || class 3 IEC 60664-1
- Bezel Material
- plastic
- Tightening Torque
- 0.5 N.m
- Output Short-Circuit Protection
- no
- Connections - Terminals
- screw terminals 1 x 4 mm² IEC 60947-1 || screw terminals 1 x 2.5 mm² IEC 60947-1
- Minimum Switching Current
- 10 mA
- Supply Voltage Limits
- 93.5-253 V AC/DC
- Temporary Permissible Current
- 10 A 0.01 s
- Ip Degree Of Protection
- front IP65 IEC 60529 || back IP20 IEC 60529
- Maximum Residual Current
- 5 mA
- Protection Type
- overvoltage protection
- Output Type
- thyristor
- Time Delay Type
- A
- Immunity To Radioelectric Fields
- 10 V level 3 IEC 61000-4-6
- Resistance To Fast Transients
- 2 kV level 3 IEC 61000-4-4