Specifications

Series Name
general purpose single mode
Electrical Connection
1 male connector 1/2"20 UNF, 3 pins
Range Of Product
Telemecanique Photoelectric sensors XU
Emission
infrared thru beam
Detection System
thru beam
Sensor Design
cylindrical M18
Supply Circuit Type
AC/DC
Line Of Sight Type
axial
Electronic Sensor Type
photo-electric sensor transmitter
Sensor Name
XU2
[Sn] Nominal Sensing Distance
15-15 m thru beam need a receiver
Material
metal
Wiring Technique
2-wire

Contractual warranty

Warranty
18 months

Complementary

Diameter
18 mm
Maximum Delay First Up
300 ms
Maximum Sensing Distance
20 m
Setting-Up
without sensitivity adjustment
Lens Material
PMMA
Supply Voltage Limits
20-264 V AC/DC
Switching Capacity In Ma
10...200 mA to be used with 0.4 A quick-blow fuse in series with the load)
Enclosure Material
Nickel Plated Brass
Add On Output
without
Length
95 mm
[Us] Rated Supply Voltage
24...240 V AC/DC

Offer Sustainability

Circularity Profile
ENVEOLI111208EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111230EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CE || CSA || UL
Ambient Air Temperature For Operation
-25-55 °C
Ambient Air Temperature For Storage
-40-70 °C
Ip Degree Of Protection
IP67 IEC 60529
Vibration Resistance
7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
Shock Resistance
30 gn 11 ms) IEC 60068-2-27