Omron
H3DK-M2 AC/DC24-240
1 / 1
- Part Number
- H3DK-M2 AC/DC24-240
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 10 Stk.Auf LagerAktualisiert am: 19-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Versandinformationen
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Ratings / Performance
- Rated supply voltage
- 24 to 240VAC 50/60 Hz
- Rated supply voltage
- 24 to 240VDC ripple: 20% max.
- Operating voltage range
- 85% to 110% of rated supply voltage
- Input signals
- Start
- Input method
- Voltage input
- Voltage input
- High (logic) level: 20.4 to 264 VAC/DC
- Voltage input
- Low (logic) level: 0 to 2.4 VAC/DC
- Minimum input signal width
- 50 ms min. (Start input)
- Power consumption ( Relay ON )
- 6.6VA(at 240 VAC)
- Power consumption ( Relay ON )
- 1.2W(at 24 VDC)
- Power consumption ( Relay OFF )
- (at 240 VAC)
- Power consumption ( Relay OFF )
- (at 24 VDC)
- Reset voltage
- 10% max. of rated supply voltage
- Number of time ranges
- 8
- Time ranges
- 0.1s~1.2s / 1s~12s / 10s~120s / 1min~12min / 10min~120min / 1h~12h / 10h~120h / 100h~1200h
- Operating mode
- ON delay, Flicker OFF start, Flicker ON start, Signal ON/OFF delay, Signal OFF delay, Interval, Signal ON/OFF delay, One shot output
- Control output (Type)
- Relay output (DPDT)
- Control output (Contact output)
- Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 30VDC 5A
- Control output (Contact output)
- Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.15A
- Control output (Contact output)
- Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.1A
- Control output (Contact output)
- Minimum applicable load: 10 mA at 5 VDC (failure level: P)
- Ambient temperature
- Operating: -20 to 55°C
- Ambient temperature
- Storage: -40 to 70°C
- Ambient humidity
- Operating: 25~85%
- Accuracy of operating time
- +/- 1% max.(FS)
- Accuracy of operating time
- (+/- 1% +/- 10 ms max. in a range of 1.2 s)
- Setting error
- -10 to 10% +/- 0.05 s max. (FS)
- Influence of voltage
- +/- 0.5% FS max. (+/- 0.5% +/- 10 ms max. in a range of 1.2 s)
- Influence of temperature
- +/- 2% FS max. (+/- 2% +/- 10 ms max. in a range of 1.2 s)
- Insulation resistance
- 100 MΩ (at 500 VDC)
- Dielectric strength
- between current carrying metal parts and non-current carrying metal parts: 2000 VAC, 50/60 Hz for 1 min
- Dielectric strength
- between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min
- Dielectric strength
- between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min
- Impulse withstand voltage
- between power terminals: 5 kV
- Impulse withstand voltage
- between exposed non-current-carrying metal parts: 5 kV
- Noise immunity
- +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise)
- Static immunity
- Mulfunction: 4 kV Destruction: 8 kV
- Vibration resistance (Destruction)
- 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 2 hours
- Vibration resistance (Malfunction)
- 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min
- Shock resistance (Destruction)
- 1000 m/s**2, 3 times each 6 directions
- Shock resistance (Malfunction)
- 100 m/s**2, 3 times each 6 directions
- Mechanical life expectancy (relayoutput)
- 10000000 operations min. (under no load at 1800 operations/h)
- Electrical life expectancy (relay output)
- 100000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
- Degree of protection
- IP30(Terminal Block: IP20)
- Weight (Main)
- Approx. 120 g