ECN0731CAA
- Nuevo1 pieza
Categorías
Volver:Todas las categoríasFiltros
StrongHold™ Locking Fork Terminal, vinyl insulated, 16 - 14 AWG, #10 Stud Size.
StrongHold™ Locking Fork Terminal, vinyl insulated, 16 - 14 AWG, #10 Stud Size.
Modular Reset Pushbutton - Momentary - Extended - Red - Non-illuminated - Black Plastic - Text/symbol: O
Modular Reset Pushbutton - Momentary - Extended - Red - Non-illuminated - Black Plastic - Text/symbol: O
Low profile 2 piece terminal cover for 3 pole T5 fixed breakers
Low profile 2 piece terminal cover for 3 pole T5 fixed breakers
Space-saving 600 volt, 30 amp molded-case fuse blocks with side barriers for isolation.
Space-saving 600 volt, 30 amp molded-case fuse blocks with side barriers for isolation.
The LCA6-14-L Tin-Plated Copper Compression Lug, one-hole, standard barrel, has color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection. An inspection window aids to visually assure full conductor insertion, and the tin-plate material helps to inhibit corrosion. UL Listed and CSA Certified to 35 KV and temperature rated to 90°C.
The LCA6-14-L Tin-Plated Copper Compression Lug, one-hole, standard barrel, has color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection. An inspection window aids to visually assure full conductor insertion, and the tin-plate material helps to inhibit corrosion. UL Listed and CSA Certified to 35 KV and temperature rated to 90°C.
The LCD6-14AF-L Tin-Plated Copper Compression Lug, two-hole, standard barrel, has color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection. An inspection window aids to visually assure full conductor insertion, and the tin-plate material helps to inhibit corrosion. UL Listed and CSA Certified to 35 KV and temperature rated to 90°C.
The LCD6-14AF-L Tin-Plated Copper Compression Lug, two-hole, standard barrel, has color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection. An inspection window aids to visually assure full conductor insertion, and the tin-plate material helps to inhibit corrosion. UL Listed and CSA Certified to 35 KV and temperature rated to 90°C.
Reducers, Enlargers, Thread Converters, Blanking Plugs, and Multi-hole Grommets are just a few of the accessories Mencom inventories to assist in providing cable entry solutions. Whether going from PG to Metric, Metric to NPT, or just plugging up an unused hole, Mencom carries the products you need.
Reducers, Enlargers, Thread Converters, Blanking Plugs, and Multi-hole Grommets are just a few of the accessories Mencom inventories to assist in providing cable entry solutions. Whether going from PG to Metric, Metric to NPT, or just plugging up an unused hole, Mencom carries the products you need.
The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
MDC connectors, sometimes referred to as Micro-DC, use an M12 coupling nut and single keyway. These versatile connectors are easy to use and provide plug and play solutions to a wide range of applications. Mencom offers molded cable, field wired connectors, panel mount receptacles, and accessories with choices of cable jackets and connector ends to meet your specific requirements. Some options for the cordsets include, PVC jacket, PUR jacket, TPE jacket, Hi-Flex cable, and shielded cable. Receptacles come in a wide range of mounting styles and threads; including Metric, PG, and NPT.
MDC connectors, sometimes referred to as Micro-DC, use an M12 coupling nut and single keyway. These versatile connectors are easy to use and provide plug and play solutions to a wide range of applications. Mencom offers molded cable, field wired connectors, panel mount receptacles, and accessories with choices of cable jackets and connector ends to meet your specific requirements. Some options for the cordsets include, PVC jacket, PUR jacket, TPE jacket, Hi-Flex cable, and shielded cable. Receptacles come in a wide range of mounting styles and threads; including Metric, PG, and NPT.
MDC connectors, sometimes referred to as Micro-DC, use an M12 coupling nut and single keyway. These versatile connectors are easy to use and provide plug and play solutions to a wide range of applications. Mencom offers molded cable, field wired connectors, panel mount receptacles, and accessories with choices of cable jackets and connector ends to meet your specific requirements. Some options for the cordsets include, PVC jacket, PUR jacket, TPE jacket, Hi-Flex cable, and shielded cable. Receptacles come in a wide range of mounting styles and threads; including Metric, PG, and NPT.
MDC connectors, sometimes referred to as Micro-DC, use an M12 coupling nut and single keyway. These versatile connectors are easy to use and provide plug and play solutions to a wide range of applications. Mencom offers molded cable, field wired connectors, panel mount receptacles, and accessories with choices of cable jackets and connector ends to meet your specific requirements. Some options for the cordsets include, PVC jacket, PUR jacket, TPE jacket, Hi-Flex cable, and shielded cable. Receptacles come in a wide range of mounting styles and threads; including Metric, PG, and NPT.
DeviceNet Drop, sometimes referred to as "Thin Cable" pairs MIN or MDC connectors with DeviceNet cabling to allow for easy plug and play connectivity in DeviceNet applications. Mencom offers many combinations of molded cables, field wired connectors, and panel mount receptacles, and DeviceNet accessories to meet your specific requirements.
DeviceNet Drop, sometimes referred to as "Thin Cable" pairs MIN or MDC connectors with DeviceNet cabling to allow for easy plug and play connectivity in DeviceNet applications. Mencom offers many combinations of molded cables, field wired connectors, and panel mount receptacles, and DeviceNet accessories to meet your specific requirements.
Pan-Alum® Self-locking Cable Ties speed up installation with a unique self-locking head design that locks into any part of the tie. Plus, the smooth edges of lightweight, flexible aluminum promote worker safety. Heavy cross section, Max bundle diameter: 4in, 14.3in, Tensile Strength: 222, 50pc.
Pan-Alum® Self-locking Cable Ties speed up installation with a unique self-locking head design that locks into any part of the tie. Plus, the smooth edges of lightweight, flexible aluminum promote worker safety. Heavy cross section, Max bundle diameter: 4in, 14.3in, Tensile Strength: 222, 50pc.
PMAFIX straight black connector with metric threads. Connector material - polyamide 6, thread material - nickel plated brass. Thread size - M25 x 1.5, thread length - 11, conduit size NW - 23.
PMAFIX straight black connector with metric threads. Connector material - polyamide 6, thread material - nickel plated brass. Thread size - M25 x 1.5, thread length - 11, conduit size NW - 23.
OHY65J6 PISTOL HANDLE
OHY65J6 PISTOL HANDLE