SRN6420K
Enclosure with blind door + back plate 600x400x200mm (HxWxD)
Enclosure with blind door + back plate 600x400x200mm (HxWxD)
- Nuevo sellado12 piezas
- Nuevo11 piezas
Filtros
Enclosure with blind door + back plate 600x400x200mm (HxWxD)
Enclosure with blind door + back plate 600x400x200mm (HxWxD)
String combiner box for photovoltaic systems up to 1000 V DC for connecting 2x 2 strings. With surge protection (type 1/2), DC fire service switch disconnector with remote access and push-in connection for the input and output sides.
String combiner box for photovoltaic systems up to 1000 V DC for connecting 2x 2 strings. With surge protection (type 1/2), DC fire service switch disconnector with remote access and push-in connection for the input and output sides.
Multi-functional energy measuring device with integrated Modbus RTU/TCP interface for measuring electrical parameters in low-voltage installations up to 690 V.
Multi-functional energy measuring device with integrated Modbus RTU/TCP interface for measuring electrical parameters in low-voltage installations up to 690 V.
Socket, Pin connector pattern type CF, Push-in spring connection, Fuse, 5 x 20 mm, 6.3 A, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
Socket, Pin connector pattern type CF, Push-in spring connection, Fuse, 5 x 20 mm, 6.3 A, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
Socket, Pin connector pattern type I, Screw connection, for China/Australia and other countries, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 10 A, -20 °C, 60 °C, GB 2099.1 and GB 1002
Socket, Pin connector pattern type I, Screw connection, for China/Australia and other countries, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 10 A, -20 °C, 60 °C, GB 2099.1 and GB 1002
16mm Selector Switch 50deg op angle, Plastic Maintained, short lever 3 position, 1NO, 1NO Complete Device White Non-Illuminated UL File E44653 in Vol.2 Sec.38
16mm Selector Switch 50deg op angle, Plastic Maintained, short lever 3 position, 1NO, 1NO Complete Device White Non-Illuminated UL File E44653 in Vol.2 Sec.38
Socket, Pin connector pattern type AB 15A, Screw connection, for USA and other countries, with LED display and switch, gray, for mounting on a DIN rail in the service interface or direct mounting, 125 V AC, 15 A, -20 °C, 60 °C, UL 508
Socket, Pin connector pattern type AB 15A, Screw connection, for USA and other countries, with LED display and switch, gray, for mounting on a DIN rail in the service interface or direct mounting, 125 V AC, 15 A, -20 °C, 60 °C, UL 508
Socket, Pin connector pattern type CF, Screw connection, Light indicator, yellow, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
Socket, Pin connector pattern type CF, Screw connection, Light indicator, yellow, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
BLANK PANEL H75-SIZE 6;BLANK PANEL H75-SIZE 6
BLANK PANEL H75-SIZE 6;BLANK PANEL H75-SIZE 6
Evaluation unit for the recording of surge currents and transient overvoltages over external sensor cables. Communication of the measured data to PROFICLOUD via Ethernet. The data evaluated in the cloud can be accessed on the device via Modbus/TCP or RESTful web service.
Evaluation unit for the recording of surge currents and transient overvoltages over external sensor cables. Communication of the measured data to PROFICLOUD via Ethernet. The data evaluated in the cloud can be accessed on the device via Modbus/TCP or RESTful web service.
String combiner box for photovoltaic systems up to 1000 V DC for connecting 4x 1 string. With surge protection (type 1/2) and Push-in connection for the input and output side.
String combiner box for photovoltaic systems up to 1000 V DC for connecting 4x 1 string. With surge protection (type 1/2) and Push-in connection for the input and output side.
Socket, Pin connector pattern type N, Screw connection, for Brazil/South Africa and other countries, LED display, green, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 20 A, -20 °C, 60 °C, NBR 14136
Socket, Pin connector pattern type N, Screw connection, for Brazil/South Africa and other countries, LED display, green, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 20 A, -20 °C, 60 °C, NBR 14136
Socket, Type: D, Push-in spring connection, for India/Africa and other countries, with LED display, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 6 A, -20 °C, 60 °C, IS 1293
Socket, Type: D, Push-in spring connection, for India/Africa and other countries, with LED display, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 6 A, -20 °C, 60 °C, IS 1293
Double socket, Pin connector pattern type CF, Screw connection, Light indicator, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
Double socket, Pin connector pattern type CF, Screw connection, Light indicator, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, VDE 0620-1
Bac roof and base for structure 1600x600x195mm (HxWxD)
Bac roof and base for structure 1600x600x195mm (HxWxD)
Sliding Cable entry flanges 1000x500mm (WxD)
Sliding Cable entry flanges 1000x500mm (WxD)
The F2C-CM motor operating device has the function to allow the remote control (opening or closing) of the RCD it is associated to. It can assembled to 2 and 4 pole RCDs of F200 range.
The F2C-CM motor operating device has the function to allow the remote control (opening or closing) of the RCD it is associated to. It can assembled to 2 and 4 pole RCDs of F200 range.
Socket, Type: D, Screw connection, for India/Africa and other countries, with LED display, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 6 A, -20 °C, 60 °C, IS 1293
Socket, Type: D, Screw connection, for India/Africa and other countries, with LED display, gray, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 6 A, -20 °C, 60 °C, IS 1293
Socket, Pin connector pattern type K, Push-in spring connection, for Denmark and other countries, green, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, SR 107-2-D1
Socket, Pin connector pattern type K, Push-in spring connection, for Denmark and other countries, green, for mounting on a DIN rail in the service interface or direct mounting, 250 V AC, 16 A, -20 °C, 60 °C, SR 107-2-D1