3NE3227
FUSE,250A,AC,1000V,SZ 1 250A, AC 1000V SITOR FUSE-LINK SIZE 1
FUSE,250A,AC,1000V,SZ 1 250A, AC 1000V SITOR FUSE-LINK SIZE 1
- Nuevo sellado198 piezas
- Nuevo46 piezas
Filtros
FUSE,250A,AC,1000V,SZ 1 250A, AC 1000V SITOR FUSE-LINK SIZE 1
FUSE,250A,AC,1000V,SZ 1 250A, AC 1000V SITOR FUSE-LINK SIZE 1
FUSE LINK, SITOR, 1A, 660V AC, 14 X 51MM SITOR CYLINDRICAL FUSE LINK AR 1 A, 660 V AC/700 V DC
FUSE LINK, SITOR, 1A, 660V AC, 14 X 51MM SITOR CYLINDRICAL FUSE LINK AR 1 A, 660 V AC/700 V DC
The C10M25 is a top-of-the-line industrial automation product from Eaton, designed to improve efficiency and productivity in manufacturing and production processes. This advanced component boasts a compact, rugged design that can withstand harsh industrial environments, and features advanced digital signal processing technology for precise control and monitoring. With a maximum current rating of 25 amps and a voltage rating of up to 600 VAC, the C10M25 is ideal for a wide range of applications, from conveyor systems to robotic assembly lines. Plus, with its user-friendly interface and easy installation, integrating the C10M25 into your existing automation system is a breeze. Trust Eaton to provide you with the highest quality industrial automation products that will help your business succeed.
The C10M25 is a top-of-the-line industrial automation product from Eaton, designed to improve efficiency and productivity in manufacturing and production processes. This advanced component boasts a compact, rugged design that can withstand harsh industrial environments, and features advanced digital signal processing technology for precise control and monitoring. With a maximum current rating of 25 amps and a voltage rating of up to 600 VAC, the C10M25 is ideal for a wide range of applications, from conveyor systems to robotic assembly lines. Plus, with its user-friendly interface and easy installation, integrating the C10M25 into your existing automation system is a breeze. Trust Eaton to provide you with the highest quality industrial automation products that will help your business succeed.
OFAF2H40 HRC Fuse Link Size NH2, gG
OFAF2H40 HRC Fuse Link Size NH2, gG
FUSE,125A,AC,690V,(GR.00) 125A , AC 690 V ,(SIZE 00) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
FUSE,125A,AC,690V,(GR.00) 125A , AC 690 V ,(SIZE 00) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
FUSE,LV HRC,300A,500VAC,SIZE 2 SIZE 2, 300A, AC 500V/DC 440V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,300A,500VAC,SIZE 2 SIZE 2, 300A, AC 500V/DC 440V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,10A,500VAC,SIZE 000 SIZE 000, 10A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,10A,500VAC,SIZE 000 SIZE 000, 10A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
2.0 AMP CYLINDRICAL FUSE LINK,500V SIZE 10X38MM, 500V 2A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE A.M.
2.0 AMP CYLINDRICAL FUSE LINK,500V SIZE 10X38MM, 500V 2A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE A.M.
This is a NFC fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a gG fuse-link that protects against thermal overloads and magnetic over currents, used in standard applications. Its current rating is 10 A and the maximum rated voltage is 400 VAC. It is a cylindrical fuse (NFC type), the dimensions are 8.5mm x 31.5mm. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 10 parts.
This is a NFC fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a gG fuse-link that protects against thermal overloads and magnetic over currents, used in standard applications. Its current rating is 10 A and the maximum rated voltage is 400 VAC. It is a cylindrical fuse (NFC type), the dimensions are 8.5mm x 31.5mm. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 10 parts.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links aM are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links aM are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links aM are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links aM are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type aM NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type aM NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
SENTRON, cylindrical fuse link, 14 x 51 mm, 40 A, gG, Un AC: 500 V
SENTRON, cylindrical fuse link, 14 x 51 mm, 40 A, gG, Un AC: 500 V
LV HRC FUSE LINK GL/GG SZ 2,50,500V SIZE 2, 50A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG