Base Unit Specifications

Hysteresis
0.03
Display
LCD, °C or °F user-selectable
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.015°C Full Range
Stability
±0.02°C at 33°C ±0.02°C at 200°C±0.03°C at 350°C
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Insert OD
25.3 mm (1.00 in)
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Power requirements
100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Radial uniformity
±0.01°C at 33°C ±0.015°C at 200°C±0.02°C at 350°C
Computer interface
RS-232 and 9930 Interface-it control software included
Weight
7.3 kg (16 lb)
Heating time
5 min: 33°C to 350°C
Cooling time
32 min: 350°C to 33°C 14 min: 350°C to 100°C
Temperature range at 23°C
33°C to 350°C (91°F to 662°F)
Resolution
0.01°
Immersion (well) depth
150 mm (5.9 in)
Axial uniformity at 40 mm (1.6 in)
±0.04°C at 33°C ±0.1°C at 200°C±0.2°C at 350°C
Display accuracy
±0.2°C Full Range

P specifications

Reference probe connection
6-pin Din with Infocon Technology
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
Reference resistance range
0 ohms to 400 ohms
RTD resistance range
0 ohms to 400 ohms
Built-in reference thermometer readout accuracy (4-Wire reference probe)1
±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
MA connection
2 terminal input
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
RTD connection
4 terminal input
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
MA range
Cal 4-22 mA, Spec 4-24 mA
TC connection
Small connectors
Voltage accuracy
0.025% of reading + 0.01 mV
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
Loop power function
24 V DC loop power
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
Reference measurement capability
4-wire
RTD measurement capability
4-wire RTD (2-,3-wire RTD w\ Jumpers only)
TC millivolt range
–10 mV to 75 mV
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD resistance accuracy‡
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
Built-in mA readout accuracy
0.02% of reading + 2 mV