Honeywell
HVFDSD3A0200G100A
1 / 3
Descripción
Honeywell variable frequency drives (VFDs) maximize energy savings by modulating the speed of fans and pumps in HVAC systems. VFDs, sometimes called inverters, achieve these savings by operating in conjunction with a building automation system (BAS) or independently through its internal PID capabilities. A Honeywell VFD is loaded with labor-saving features such as startup wizards, PC programming and an intuitive graphical interface that allows for faster, more accurate commissioning.- Part Number
- HVFDSD3A0200G100A
€1,316.64
net€1,462.94
Envío desde:
€80.00
1
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 1 piezaEn stockActualizado en: 19-11-2024
- Garantía:
- 24 meses
- Entrega Estimada:
- 09-11 diciembre a Reino Unido
- Condición:
- Reacondicionado
Reacondicionado - Un artículo reacondicionado inspeccionado, limpiado y reparado para que funcione completamente por el fabricante o un técnico certificado. El artículo está en excelente estado y completamente operativo.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Specifications
- Relay Rated Load
- Max load: 250Vac/8A- 24Vdc/8A- 125Vdc/0.4A
- Regulatory Approvals
- CE ; EN 61800-5-1 ; cUL
- Reference Output Voltage
- 10 Vdc- max load 10 mA
- Peak Current
- IS- 2s/20s
- Overall Width
- 7.7 in ; 196 mm
- Overall Weight
- 20 ; 44.1
- Overall Height
- 21.9 in ; 556 mm
- Overall Depth
- 9 in ; 229 mm
- Output Voltage
- 208/230 (3PH) V AC
- Minimum Shipping & Storage Temperature
- -40 °F ; -40 °C
- Minimum Operating Humidity
- 0 %
- Minimum Operating Ambient Temperature
- 14 °F ; -10 °C
- Minimum Deceleration time
- 0.1 s
- Minimum Acceleration time
- 0.1 s
- Maximum Shipping & Storage Temperature
- 158 °F ; 70 °C
- Maximum Operating Humidity
- 95 %
- Maximum Operating Ambient Temperature
- 104 °F ; 40 °C
- Maximum Deceleration time
- 3000 s
- Maximum Acceleration time
- 3000 s
- Frame Type
- MR6
- Drive Input Disconnect
- No
- Continuous Output Current
- Overload: 1.1 x IL- 1 min / 10 min
- Bypass/Disconnect Options
- Drive alone
- Analog Outputs
- 0-10Vdc- RL 1kΩ; 0(4)-20mA- RL 500Ω- Selectable
- Analog Inputs
- 0-10Vdc- Ri = 200kΩ; 0(4)-20mA- Ri = 250Ω- 2 Selectable
- Current Ratings
- 62 A
- Drive Family
- SmartVFD HVAC
- Type of RFI Filter
- EMC Filter
- Application
- Variable Torque Only
- Enclosure Type
- NEMA 1
- Horsepower
- 20 HP
- Input Voltage
- 208/230 (3PH) V AC
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros