- Mtbf Reliability
- 3200000 H
- Network Frequency
- 50/60 Hz
- Voltage Range
- 5...150 V || 19...264 V
- Minimum Switching Current
- 1 mA 5 V DC
- Status Led
- 1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
- Insulation Resistance
- > 10 MOhm 500 V DC
- Network Frequency Limits
- 47-63 Hz
- [Ith] Conventional Free Air Thermal Current
- 3 A
- Protection Type
- external short-circuit protection || external overload protection || external overvoltage protection, inductive AC || external overvoltage protection, inductive DC
- Power Dissipation In W
- 3.6 W
- Net Weight
- 0.169 kg
- Electrical Connection
- 20 ways terminal block
- Electrical Durability
- AC-12 200000 cycles 48 VA 24 V 0-60 °C || AC-12 300000 cycles 48 VA 48 V 0-60 °C || AC-12 150000 cycles 96 VA 48 V 0-60 °C || AC-12 300000 cycles 110 VA 100...120 V 0-60 °C || AC-12 150000 cycles 220 VA 100...120 V 0-60 °C || AC-12 300000 cycles 220 VA 200...250 V 0-60 °C || AC-12 150000 cycles 500 VA 200...250 V 0-60 °C || AC-15 700000 cycles 10 VA 24 V 0-60 °C 0.4 ) || AC-15 500000 cycles 24 VA 24 V 0-60 °C 0.4 ) || AC-15 200000 cycles 48 VA 24 V 0-60 °C 0.4 ) || AC-15 700000 cycles 10 VA 48 V 0-60 °C 0.4 ) || AC-15 500000 cycles 24 VA 48 V 0-60 °C 0.4 ) || AC-15 300000 cycles 48 VA 48 V 0-60 °C 0.4 ) || AC-15 100000 cycles 96 VA 48 V 0-60 °C 0.4 ) || AC-15 1000000 cycles 10 VA 100...120 V 0-60 °C 0.4 ) || AC-15 300000 cycles 50 VA 100...120 V 0-60 °C 0.4 ) || AC-15 200000 cycles 110 VA 100...120 V 0-60 °C 0.4 ) || AC-15 70000 cycles 220 VA 100...120 V 0-60 °C 0.4 ) || AC-15 1000000 cycles 10 VA 200...250 V 0-60 °C 0.4 ) || AC-15 500000 cycles 50 VA 200...250 V 0-60 °C 0.4 ) || AC-15 200000 cycles 110 VA 200...250 V 0-60 °C 0.4 ) || AC-15 150000 cycles 220 VA 200...250 V 0-60 °C 0.4 ) || DC-12 200000 cycles 24 W 24 V 0-60 °C || DC-12 150000 cycles 48 W 24 V 0-60 °C || DC-12 150000 cycles 40 W 48...60 V 0-60 °C || DC-12 100000 cycles 45 W 100...125 V 0-60 °C || DC-13 100000 cycles 10 W 24 V 0-60 °C || DC-13 60000 cycles 24 W 24 V 0-60 °C || DC-13 40000 cycles 48 W 24 V 0-60 °C || DC-13 40000 cycles 40 W 48...60 V 0-60 °C || DC-13 100000 cycles 15 W 100...125 V 0-60 °C
- Typical Current Consumption
- 40 mA 3.3 V DC || 101 mA 24 V DC
- Output Overvoltage Protection
- use discharge diode on each output DC || use RC circuit on each output AC || use ZNO surge limiter on each output AC
- Output Short-Circuit Protection
- use 1 fast blow fuse per channel or group of channel
- Output Overload Protection
- use 1 fast blow fuse per channel or group of channel
- Response Time On Output
- <= 10 ms activation || <= 13 ms deactivation