Schneider Electric
BMXDRC0805H
discrete module X80 - 8 NO/NC Type C - Isolated relays - 125 V DC/250 V AC - sev
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€342.84
Additional Information
- Part Number
- BMXDRC0805H
- Tariff Code
- 8537109170
Complementary
- Mtbf Reliability
- 2650000 H
- Network Frequency
- 50/60 Hz
- Voltage Range
- 5...150 V || 19...264 V
- Electrical Durability
- AC-12 200000 cycles 48 VA 24 V -25-60 °C || AC-12 200000 cycles 28.8 VA 24 V 60-70 °C || AC-12 300000 cycles 48 VA 48 V -25-60 °C || AC-12 300000 cycles 28.8 VA 48 V 60-70 °C || AC-12 150000 cycles 96 VA 48 V -25-60 °C || AC-12 150000 cycles 57.6 VA 48 V 60-70 °C || AC-12 300000 cycles 110 VA 100...120 V -25-60 °C || AC-12 300000 cycles 66 VA 100...120 V 60-70 °C || AC-12 150000 cycles 220 VA 100...120 V -25-60 °C || AC-12 150000 cycles 132 VA 100...120 V 60-70 °C || AC-12 300000 cycles 220 VA 200...250 V -25-60 °C || AC-12 300000 cycles 132 VA 200...250 V 60-70 °C || AC-12 150000 cycles 500 VA 200...250 V -25-60 °C || AC-12 150000 cycles 300 VA 200...250 V 60-70 °C || AC-15 700000 cycles 10 VA 24 V -25-60 °C 0.4 ) || AC-15 700000 cycles 6 VA 24 V 60-70 °C 0.4 ) || AC-15 500000 cycles 24 VA 24 V -25-60 °C 0.4 ) || AC-15 500000 cycles 14.4 VA 24 V 60-70 °C 0.4 ) || AC-15 200000 cycles 48 VA 24 V -25-60 °C 0.4 ) || AC-15 200000 cycles 28.8 VA 24 V 60-70 °C 0.4 ) || AC-15 700000 cycles 10 VA 48 V -25-60 °C 0.4 ) || AC-15 700000 cycles 6 VA 48 V 60-70 °C 0.4 ) || AC-15 500000 cycles 24 VA 48 V -25-60 °C 0.4 ) || AC-15 500000 cycles 14.4 VA 48 V 60-70 °C 0.4 ) || AC-15 300000 cycles 48 VA 48 V -25-60 °C 0.4 ) || AC-15 300000 cycles 28.8 VA 48 V 60-70 °C 0.4 ) || AC-15 100000 cycles 96 VA 48 V -25-60 °C 0.4 ) || AC-15 100000 cycles 57.6 VA 48 V 60-70 °C 0.4 ) || AC-15 1000000 cycles 10 VA 100...120 V -25-60 °C 0.4 ) || AC-15 1000000 cycles 6 VA 100...120 V 60-70 °C 0.4 ) || AC-15 300000 cycles 50 VA 100...120 V -25-60 °C 0.4 ) || AC-15 300000 cycles 30 VA 100...120 V 60-70 °C 0.4 ) || AC-15 200000 cycles 110 VA 100...120 V -25-60 °C 0.4 ) || AC-15 200000 cycles 66 VA 100...120 V 60-70 °C 0.4 ) || AC-15 70000 cycles 220 VA 100...120 V -25-60 °C 0.4 ) || AC-15 70000 cycles 132 VA 100...120 V 60-70 °C 0.4 ) || AC-15 1000000 cycles 10 VA 200...250 V -25-60 °C 0.4 ) || AC-15 1000000 cycles 6 VA 200...250 V 60-70 °C 0.4 ) || AC-15 500000 cycles 50 VA 200...250 V -25-60 °C 0.4 ) || AC-15 500000 cycles 30 VA 200...250 V 60-70 °C 0.4 ) || AC-15 200000 cycles 110 VA 200...250 V -25-60 °C 0.4 ) || AC-15 200000 cycles 66 VA 200...250 V 60-70 °C 0.4 ) || AC-15 150000 cycles 220 VA 200...250 V -25-60 °C 0.4 ) || AC-15 150000 cycles 132 VA 200...250 V 60-70 °C 0.4 ) || DC-12 200000 cycles 24 W 24 V -25-60 °C || DC-12 200000 cycles 14.4 W 24 V 60-70 °C || DC-12 150000 cycles 48 W 24 V -25-60 °C || DC-12 150000 cycles 28.8 W 24 V 60-70 °C || DC-12 150000 cycles 40 W 48...60 V -25-60 °C || DC-12 150000 cycles 24 W 48...60 V 60-70 °C || DC-12 100000 cycles 45 W 100...125 V -25-60 °C || DC-12 60000 cycles 45 W 100...125 V 60-70 °C || DC-13 100000 cycles 10 W 24 V -25-60 °C || DC-13 100000 cycles 6 W 24 V 60-70 °C || DC-13 60000 cycles 24 W 24 V -25-60 °C || DC-13 60000 cycles 14.4 W 24 V 60-70 °C || DC-13 40000 cycles 48 W 24 V -25-60 °C || DC-13 40000 cycles 28.8 W 24 V 60-70 °C || DC-13 40000 cycles 40 W 48...60 V -25-60 °C || DC-13 40000 cycles 24 W 48...60 V 60-70 °C || DC-13 100000 cycles 15 W 100...125 V -25-60 °C || DC-13 40000 cycles 15 W 100...125 V 60-70 °C
- Typical Current Consumption
- 40 mA 3.3 V DC || 101 mA 24 V DC
- Minimum Switching Current
- 10 mA 5 V DC
- [Ith] Conventional Free Air Thermal Current
- 4 A 40 °C || 3 A 50 °C || 2 A 60 °C || 1.2 A 70 °C
- Output Overvoltage Protection
- use discharge diode on each output DC || use RC circuit on each output AC || use ZNO surge limiter on each output AC
- Status Led
- 1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
- Output Short-Circuit Protection
- use 1 fast blow fuse per channel or group of channel
- Output Overload Protection
- use 1 fast blow fuse per channel or group of channel
- Insulation Resistance
- > 10 MOhm 500 V DC
- Network Frequency Limits
- 47-63 Hz
- Protection Type
- external short-circuit protection || external overload protection || external overvoltage protection, inductive AC || external overvoltage protection, inductive DC
- Power Dissipation In W
- 3.6 W
- Net Weight
- 0.189 kg
- Response Time On Output
- <= 10 ms activation || <= 13 ms deactivation
- Electrical Connection
- 40 ways terminal block
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 0-95 % -25-70 °C without condensation
- Operating Altitude
- 0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
- Shock Resistance
- 30 gn
- Environmental Characteristic
- gas resistant class Gx || gas resistant class 3C4 || dust resistant class 3S4 || sand resistant class 3S4 || salt resistant level 2 || mold growth resistant class 3B2 || fungal spore resistant class 3B2
- Dielectric Strength
- 1780 V AC 50/60 Hz 1 min
- Vibration Resistance
- 3 gn
- Protective Treatment
- conformal coating
- Ip Degree Of Protection
- IP20
Specifications
- Range Of Product
- Modicon X80
- Discrete Output Number
- 8 EN/IEC 61131-2
- Discrete Output Logic
- positive or negative
- Product Specific Application
- for severe environments
- Discrete Output Voltage
- 5...125 V 5...150 V DC || 24...240 V 19...264 V AC
- Product Or Component Type
- relay discrete output module
Offer Sustainability
- China Rohs Regulation
- X
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Documentos
Data Sheet
DescargarOtras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros